5.4.2 Dip Switch Settings
• Tripod Turnstiles:
Time out and mode settings of the turnstile are selected by the dip switch located on the
control board as explained below.
FIG
FIG 11
FIG
FIG 22
FIG
FIG 44
FIG
FIG 33
B
A
B
A
B
A
B
A
FUNTION (PROGRAM) SELECTION
3
1
3
2
4
4
DIAGRAM
DIPSWITCH
FUNCTION
OFF
Bi-directional operation
A-B free, B-A controlled access
Single input, activation in both directions
B-A free, A-B controlled access
OFF
OFF
OFF
ON
ON
ON
ON
TIME SETUP
DIPSWITCH
1
2
TIME
OFF
OFF
6 sec.
12 sec.
18 sec.
INFINITY
OFF
OFF
ON
ON
ON
ON
SWITCH NO
1
TIME SETUP 1
TIME SETUP 2
PROGRAM SETUP 1
PROGRAM SETUP 2
2
3
4
EXPLANATION
ON
OFF
ON
OFF
ON
OFF
FIG 1.
Bi-directional controlled passage: A card reader or button is used for each direction
FIG 2.
Bi- directional passage by a single control device: A single reader or button connected into In A
allows passage in both directions
FIG 3.
A direction free, B direction controlled passage: Example: Controlled entry –free exit into a building.
FIG 4.
B direction free, A direction controlled passage
• Wide Access/ DDA Models:
Switch number 2: Sets ‘stay open’ duration to 2 seconds. Default is 6 seconds.
Switch number 3: Sets emergency opening direction
Switch number 4: Allows open/ timeout reset -close commands by a single
contact into In A or B. Panel closes without waiting for timeout period
when input contact is repeated.
All other settings are as explained in table above
TSC Manager app allows quick access to turnstile settings
with on/off switch options in the menu.
TSC Manager application can be downloaded from google
playstore which is available in all android phones. Scan the