7
5.
TECHNICAL DATA
a)
Supplier's name or trade mark
OXYGEN
b) Model identifier
X-Air C200E
c)
Specific energy consumption (SEC), SEC class
A
Warm climate
kWh/m
2
.a
-15.9
Average climate
kWh/m
2
.a
-39.5
Cold climate
kWh/m
2
.a
-76.0
d) Declared typology
Bi-directional,
residential ventilation
e)
Type of drive installed or intended to be installed
Variable speed drive
f)
Type of heat recovery system
Recuperative
g) Thermal efficiency of heat recovery
%
75.1
h) Maximum flow rate
m
3
/h
143
i)
Electric power input of the fan drive, including
any motor control equipment, at maximum flow
rate
W
106
j)
Sound power level (L
WA
)
49
k)
Reference flow rate
m
3
/s
0.0278
l)
Reference pressure difference
Pa
50
m) Specific power input (SPI)
W/(m3/h) 0.298
n) Control factor
0.65
Control typology
Local demand control
o) Declared maximum leakage rate:
internal
%
2.31
external
%
1.16
q) Position and description of visual filter warning
Refer to user´s manual
s)
Internet
address
for
pre-/dis-assembly
instructions
www.oxygen.lt
v)
The annual electricity consumption (AEC)
Warm climate
kWh/m
2
.a 1.6
Average climate
kWh/m
2
.a 2.0
Cold climate
kWh/m
2
.a 7.4
w) The annual heating saved (AHS)
Warm climate
kWh/a
19.8
Average climate
kWh/a
43.8
Cold climate
kWh/a
85.8
According to commission delegated regulation (EU) No. 1254/2014
Summary of Contents for X-Air C200E