Cautions, Warnings and Hazards for working with ozone.

Refer to the manual of the ozone generating system first, to assure proper location of all
ozone equipment.

Ozone is a powerful oxidizing agent.  Observe strict operating procedures when using 
ozone equipment.

Ensure that the ozone system is in a well-ventilated area.  The OA-1 Ozone Alarm must 
be used indoors mounted 5-6 ft. from the floor.

Note:  If the operator has asthma, he/she must not enter an ozonated airspace.

Ozone can induce an asthma attack.

Carefully review and familiarize yourself with the following important safety information 
statements concerning the use of ozone.

WARNING

Ozone is an extremely aggressive and powerful oxidizer. The 
Occupational Safety and Health Administration (OSHA) 8-
hour exposure limit is 0.10-PPM. The OSHA 15-minute 
exposure limit for ozone is 0.3 PPM.  Above 0.3 PPM, there is
the risk of damage to respiratory tissues.

WARNING 

People who have no sense of smell should not operate this 
equipment.

WARNING

 

Never

 attempt to verify ozone production by directly breathing

or smelling the ozone outlet or an ozone-tubing outlet.

WARNING

 

Make sure all tubing connections between the ozone 
generator and the injection point are secure and in good 
working condition.  Failure to do so could result in the 
discharge of undesired ozone into an occupied space.

Page 2

214 West Highway 18

Inwood, IA 51240

PH: (515) 635-5854

Summary of Contents for OA-1

Page 1: ...OA 1 Ozone Alarm Installation and Operation Manual Page 1 214 West Highway 18 Inwood IA 51240 PH 515 635 5854...

Page 2: ...ements concerning the use of ozone WARNING Ozone is an extremely aggressive and powerful oxidizer The Occupational Safety and Health Administration OSHA 8 hour exposure limit is 0 10 PPM The OSHA 15 m...

Page 3: ...arnings and Hazards 2 Table of Contents 3 Introduction 4 Features 4 Specifications 5 Installation 5 Operation 6 Internal Components 7 Wiring Diagram 8 System Maintenance 9 Contact Info 10 Page 3 214 W...

Page 4: ...tures Red strobe light will alert of ozone levels above set point Audible siren will alert of ozone levels above set point Volume can be adjusted simply by turning the cover of the siren User settable...

Page 5: ...e semiconductor sensor Size 11 long x 4 5 deep x 8 wide Weight 1 lb Power requirements 12 VDC at 300 mA AC adapters available worldwide Relay Outputs 10 amp relay Analog output 4 20 mA output linear w...

Page 6: ...m up press the brown button on the circuit board inside to perform a zero calibration make sure this is done in an ozone free environment After 12 hours of warm up perform a zero calibration once more...

Page 7: ...Internal components Page 7 214 West Highway 18 Inwood IA 51240 PH 515 635 5854...

Page 8: ...Wiring Diagram Page 8 214 West Highway 18 Inwood IA 51240 PH 515 635 5854...

Page 9: ...of any of these components fail please contact the manufacturer MONTHLY Perform a zero calibration Clean Alarm Bump test with ozone ANNUALLY SM 3 Ozone Leak Sensor Replace Page 9 214 West Highway 18...

Page 10: ...ontact Info By mail Oxidation Technologies LLC 214 West Highway 18 Inwood IA 51240 By telephone 515 635 5854 By e mail info oxidationtech com Page 10 214 West Highway 18 Inwood IA 51240 PH 515 635 585...

Reviews: