ВЗР.248100.000OM
Gate K-14
Operation Manual
12
2.2.4
Control panel settings
– CP appearance. The product can be installed in different ways
relative to the user. In some cases, it is necessary to swap left/right passage
buttons. This can be done using the following procedure:
1)
Turn power on;
2)
Press and hold
left
(1) and
right
(3) buttons until the LEDs on the
left
(1) and
right
(3)
buttons blink. Turn power on;
3)
Press and release the
stop
(2) button;
4)
Press and release the
left
button (1).
Now when LEFT button is pressed, it will be allowed to pass to the right
and vice versa. Current button assignment is stored and not reset when the power
is turned off. To return to the initial setting, repeat the above sequence of
operations.
– control buttons 1 (LEFT), 2 (STOP), 3 (RIGHT), 4 (ANTI-PANIC)
and LED indicators of the product operating modes.
Figure 3
– Control panel appearance
1