background image

3

Safety can no longer be insured if the Voltage Tester:

• Shows obvious damage
• Does not carry out the desired measurements
• Has been stored for too long under unfavourable conditions
• Has been subjected to mechanical stress during transport.  

All relevant statutory regulations must be adhered to when using this instrument

Safety Advice

• Depending on the internal impedance of the Voltage Tester there will be a different capability  

of indicating the presence or absence of operating voltage in case of the presence of 

interference voltage.

• A Voltage Tester of relatively low internal impedance, compared to the reference value of  

100kΩ, will not indicate all interference voltages having an original voltage value above the 

ELV (Extra Low Voltage) level. When in contact with the parts to be tested, the Voltage Tester 

may discharge temporarily the interference voltage to a level below the ELV, but it will be back 

to the original value when the Voltage Tester is removed.

• When the indication “voltage present” does not appear, it is highly recommended installing 

earthing equipment before work.

• A Voltage Tester of relatively high internal impedance, compared to the reference value of 100kΩ, 

may not permit to clearly indicate the absence of operating voltage in case of presence of interference 

voltage.

• When the indication “voltage present” appears on a part that is expected to be disconnected 

of the installation, it is highly recommended confirming by another means (e.g. use of an 

adequate voltage detector, visual check of the disconnecting point of the electric circuit, etc.) 

that there is no operating voltage on the part to be tested and to conclude that the voltage 

indicated by the Voltage Tester is an interference voltage.

• A Voltage Tester declaring two values of internal impedance has passed a performance test 

of managing interference voltages and is (within technical limits) able to distinguish operating 

voltage from interference voltage and has a means to directly or indirectly indicate which type 

of voltage is present.

Appropriate Usage

The instrument may only be used under those conditions and for those purposes for which it 

was conceived. For this reason, in particular the safety references, the technical data including 

environmental conditions and the usage in dry environments must be followed. When modifying  

or changing the Voltage Tester, the operational safety is no longer ensured. The Voltage Tester 

may only be opened by an authorised service technician, e.g. for fuse replacement. The Voltage 

Tester is designed to be used by skilled persons and in accordance with safe methods of work. 

Summary of Contents for OXD-516-8260F

Page 1: ...CZ HU PL SK TH cromwell co uk Voltage test up to 1000V AC DC Single pole phase test Continuity test Rotary field indication Polarity indication Hold function CAT III 1000V CAT IV 600V LCD backlight C...

Page 2: ...t receive utmost attention when working with voltages exceeding 120V 60V DC or 50V 25V rms AC The values in brackets are valid for limited ranges as for example medicine and agriculture Prior to measu...

Page 3: ...learly indicate the absence of operating voltage in case of presence of interference voltage When the indication voltage present appears on a part that is expected to be disconnected of the installati...

Page 4: ...atic Polarity detection Full range Internal basic load impedance peak current Maximum 3 5mA at 690V 200k Is 3 5 mA no RCD tripping Operation time Duration Time 30 seconds Recovery time Recovery Time 2...

Page 5: ...er4 mm screw on BEFORE USING THE VOLTAGE TESTER Ensure that the Voltage Tester is in perfect condition For example keep an eye out for a broken housing or leaking batteries Before using at locations w...

Page 6: ...elete the recorded value press the HOLD button once again The LCD and LEDs display once again indicates the voltage currently being applied to the probe tips SINGLE POLE PHASE TEST The single pole pha...

Page 7: ...e battery power the Voltage Tester will automatically turn off after 4 minutes MEASUREMENT POINT ILLUMINATION The Voltage Tester is equipped with a measurement point illumination feature Press the but...

Page 8: ...s that have reached the end of their life must be collected separately and returned to an environmentally compatible recycling facility Do not dispose of electrical goods with domestic waste materials...