12
RUNNING FOR THE FIRST TIME
Plug the unit into the mains, (single phase, 3 pin,13 amp
socket) using an PRCD to help protect
the user. Press the
black button to start the motor and the red one to stop the
motor.
GREASING
The ram collar needs to be greased where it slides down
the guide, this will help to reduce the friction and help the
unit run more smoothly. This needs to be carried out every
10 hours or alternatively at the start of each day.
25
2. Storage
The motors should be stored in a dry and well-ventilated
indoor storage. Should not be stored in a storage which is
full of corrosive gas
.
III. Preliminaries Before Operation
1.Check the InsuIation Resistance
Before the motor is put into operation the insulation
resistance between its winding and that of the windings
respect to ground with a megaohm meter of 500V. The rate
of the resistance is more than 1.0 megaohm, otherwise, the
winding should be treated with heat-baking.
If it is available a voltage in the range of 1/3 to 1/2 of the
rated value can be applied to get the motor running at no
Ioad one hour or so, untiI the dampness is expelled.
2. Check the line Voltage
Connect the Iine voltage in accordance with the value
indicated on the nameplate of the motors
.
To the double
voltage motor should be more care the motor voltage and
power voltage just the same on the connection plate