4.Advanced User Guidebook
74
Figure 4-20
Rise Time:
Time that the leading edge of the first pulse in the waveform
takes to rise from 10% to 90% of its amplitude.
Fall Time:
Time that the falling edge of the first pulse in the waveform
takes to fall from 90% to 10% of its amplitude.
+D width:
The width of the first positive pulse in 50% amplitude points.
-D width:
The width of the first negative pulse in the 50% amplitude points.
+Duty:
+Duty Cycle, defined as +Width/Period.
-Duty:
-Duty Cycle, defined as -Width/Period.
Delay
A→B
:
The delay between the two channels at the rising edge.
Delay
A→B
:
The delay between the two channels at the falling edge.
Screen Duty:
Defines as (the width of the positive pulse)/(Entire period)
Phase
A→B
:
Phase difference calculated according to " Delay
A→B "
and the period of source A, expressed in degree. The calculation formula
is as shown below:
Phase
A→B = (Delay A→B ÷ Period of source A) × 360°
Phase
A→B
:
Phase difference calculated according to " Delay
A→B "
and the period of source A, expressed in degree. The calculation formula
is as shown below:
Phase
A→B = (Delay A→B ÷ Period of source A) × 360°
Note for the following delay measurements:
Source A and Source B can be set in the automatic measurement function menu.
FRR
: Time between Source A first rising edge and Source B first rising edge.
FRF
: Time between Source A first rising edge and Source B first falling edge.
Summary of Contents for TAO3000 Dual-Channel Series
Page 1: ...TAO3000 Dual Channel Series Tablet Oscilloscopes User Manual www owon com ...
Page 93: ...4 Advanced User Guidebook 87 Figure 4 24 Hamming window Figure 4 25 Rectangle window ...
Page 94: ...4 Advanced User Guidebook 88 Figure 4 26 Blackman window Figure 4 27 Hanning window ...
Page 95: ...4 Advanced User Guidebook 89 Figure 4 28 Kaiser window Figure 4 29 Bartlett window ...