![Owon PDS8102T User Manual Download Page 68](http://html.mh-extra.com/html/owon/pds8102t/pds8102t_user-manual_1664711068.webp)
User Manual of
OWON
Color Mixed Signal Digital Storage Oscilloscope
65
Wave
Only show one or two periods.
Show Multi-period waveforms.
If you want to measure the two-channel signal, you can do as the follows:
1.
Press
Autoscale
, the function menu will appear on the right of the screen.
2.
Press
F1
and choose
ON.
3.
Press
F2
and choose Horizontal- Vertical for
Mode
item.
4.
Press
F3
and
choose
for
Wave
item.
Then the wave is displayed in the screen,showon as
Fig.5-51
.
Fig.5-51
: Autoscale Horizontal- Vertical multi-period waveforms
Note:
1.
Entering into Autoscale function
and
flicker will be on the top left corner.
(flicker every 0.5 second)
2.
At the mode of Autoscale, the oscilloscope can self-estimate “Trigger Type” (Edge,
Video, and Alternate) and “mode” (Edge, Video). If now, you press “Trigger mode” or
“Type”, the forbidden information will display on the screen.
3.
At the mode of XY and STOP status, pressing
AUTO SET
to enter into Autoscale,
DSO switches to YT mode and AUTO status.
4.
At the mode of Autoscale, DSO is always in the state of DC coupling and AUTO
triggering. In this case, the forbidden information will be showing when making
Triggering or Coupling settings.
5.
At the mode of Autoscale, if adjust the vertical position, voltage division, trigger level
or time scale of CH1 or CH2, the oscilloscope will turn off Autoscale function and if
press
AUTOSET
again, the oscilloscope will enter into Autoscale.