User Manual of
OWON
Color Mixed Signal Digital Storage Oscilloscope
44
Alternate trigger(Trigger Mode: Slope )
Alternate trigger(Trigger Type:
Slope
)Menu is shown as Fig.5-26.
Fig.5-26
Alternate trigger(Trigger Type:
Slope
)Menu
Alternate trigger(Trigger Type:
Slope
) menu list:
MENU SETTING
INSTRUCTION
Source
CH1
CH2
S
elect CH1 as the trigger source.
Select CH2 as the trigger source.
Mode
Slope
Slope
Condition
Rising Edge and more than.
Rising Edge and less than.
Rising Edge and equal to .
Falling Edge and more than
Negative pulse and less than
Negative pulse and equal to
settings
24ns~10s
Turn “TRIG LEVEL”knob to set slope time
High level
Turn“TRIG LEVEL”knob to set the
High level
Low level
Turn “TRIG LEVEL”knob to set
Low level
Slew rate
Slew rate=(
High level- Low level)/ Settings
Coupling
AC
DC
HF
LF
Not allow DC portion to pass.
Allow all portion pass.
Not allow high frequency of signal pass and only low
frequency portion pass.
Not allow low frequency of signal pass and only high
frequency portion pass
Holdoff
100ns
~
10s
Turn “TRIG LEVEL” knob to set time slot before another
trigger event
Holdoff
Reset
Reset hold time to 100ns