How to Use Executive Buttons
AUTOSET
This button is used for the automatic setting of all control values of the instrument to
generate the waveform suitable for observation. Press the
AUTOSET
button and the
oscilloscope will perform the fast automatic measurement of the signal.
The function items of
AUTOSET
are shown as the following table:
Function Items
Setting
Acquisition Mode
Current
Vertical Coupling
DC
Vertical Scale
Adjust to the proper division.
Bandwidth Full
Horizontal Level
Middle
Horizontal Sale
Adjust to the proper division
Trigger Type
Current
Trigger Source
Show the minimum number of channels.
Trigger Coupling
Current
Trigger Slope
Current
Trigger Level
Mid-point Setting
Trigger Mode
Auto
Display Format
YT
RUN/STOP
Enable or disable the waveform sampling.
Notice:
Under the
Stop
state, the vertical division and the horizontal time base of the
waveform can be adjusted within a certain range, in other words, the signal
can be expanded in the horizontal or vertical direction.
When the horizontal time base equal to or is less than 50ms, the horizontal
time base can be expanded for 4 divisions downwards.
U-DISK COPY
Insert U disk into USB port, then press “COPY” key and you can save the waveform data into
the U disk. There is two formats available for choice: Vector format and Bitmap which the
corresponding name will be WAVE1.BIN
、
WAVE2.BIN
、
WAVE3.BIN……or WAVE1.BMP
、
WAVE2.BMP
、
WAVE3.BMP……. Then you can open the files in computer by connecting
USB disk to computer.
Noted: During the U disk saving procedure, some notes such as “Waveform saving”
、
“Waveform saved”
、
“USB already connected”
、
“USB connection interrupt ” etc will be
prompted.