Do  not  use  any  abrasive  chemical  cleaning  agent  to  avoid  damaging  the 

instrument or probe. 

Warning

: Please make sure the instrument is dry before re-energizing 

to avoid electrical short circuit or personal injury caused by moisture. 

 

Charging and Replacement of Battery 

During the long-term storage of the device, the battery may be too low due to

 the self-discharge of the lithium battery and the device cannot be turned on. 

This is a normal phenomenon. 

Please use the attached adapter to pre-charge the device for 0.5 to 1 hour (d

epending on the storage time) before turning it on. In addition, if the device is

 not used for a long time, it is recommended to charge it at regular intervals t

o avoid over-discharge of the lithium battery. 

Battery Charging 

The  lithium  battery  may  not  be  fully  charged  when  delivered.  To  make  the 

battery fully charged, it takes up to 

4.5 hours (when the device is turned off) 

or it is subject to the charging indicator. After charging, the battery can supply 

power for about 

4 hours. 

The power supply and battery indicator symbols in the upper right corner  of 

the screen are explained as follows: 

  symbol indicates the power-on charging status; 

  symbol indicates battery power supply; 

  symbol  indicates  that  there  is  only  about  five  minutes  of  use  time  left. 

Please  charge  as  soon  as  possible  according  to  the  relevant  tips  to  avoid 

damage to the battery. 

Charging Method 

Charging the battery through the power adapter: Connect the oscilloscope to 

Summary of Contents for HDS200 Series

Page 1: ...HDS200 Dual Channel Series Handheld Oscilloscope User Manual HDS272 S HDS242 S HDS2102 S For product support visit www owon com hk download ...

Page 2: ...eplace all materials published The information in this manual was correct at the time of printing However LILLIPUT will continue to improve products and reserves the rights to change specification at any time without notice is the registered trademark of the LILLIPUT Company Fujian LILLIPUT Optoelectronics Technology Co Ltd No 19 Heming Road Lantian Industrial Zone Zhangzhou 363005 P R China Tel 8...

Page 3: ...tre a copy of the customers proof of purchase is also required This warranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care We shall not be obligated to furnish service under this warranty a to repair damage resulting from attempts by personnel other than our company representatives to install repair or service the product b to...

Page 4: ...nt Setting 13 Safe Use of Probe 14 Vertical System 15 Horizontal System 16 Measuring System 17 4 HOW TO USE THE MULTIMETER 23 About This Chapter 23 Instrument Interface 24 5 HOW TO USE THE WAVEFORM GENERATOR OPTIONAL 26 Connect the output 26 Set the waveform 26 Set the load 26 Output the sine waveform 27 Output the square waveform 28 Output the ramp waveform 28 Output the pulse waveform 28 Output ...

Page 5: ...ii Multimeter 35 Arbitrary Waveform Generator Optional 36 General Technical Specifications 38 9 APPENDIX 39 Appendix A List of Accessories 39 Appendix B Maintenance and Cleaning 39 ...

Page 6: ...ay appear on this product Danger Indicates an immediate hazard or injury possibility Warning Indicates a possible hazard or injury Caution Indicates potential damage to the instrument or other property Safety Symbols Symbols on the product The following symbol may appear on the product Hazardous Voltage Refer to Manual Protective Earth Terminal Chassis Ground Test Ground Safety Requirements Please...

Page 7: ...y cause a short circuit due to the ground wire connection of the oscilloscope probe Warning Note that the channel should use a common reference when measuring otherwise it may cause a short circuit due to the ground wire connection of the oscilloscope probe Schematic diagram of the internal ground wire connection of the oscilloscope Ground Clip Signal Input Electrical Outlet Probe AC Adapter Oscil...

Page 8: ...oscope probes and accessories power adapter USB etc Firstly plug the power adapter into the AC socket and then connect it to the oscilloscope When testing in a CAT II environment do not connect a voltage higher than 400 V to any input port When testing in a CAT II environment do not connect a voltage with a voltage difference of more than 400 V to the isolated input port Do not use an input voltag...

Page 9: ... Using the equipment not in accordance with the method specified by the manufacturer may damage the protection provided by the equipment 2 How to Implement the General Inspection After you get a new oscilloscope it is recommended that you should make a check on the instrument according to the following steps 1 Check whether there is any damage caused by transportation If it is found that the packa...

Page 10: ...please keep the package With the transportation department or our distributor responsible for this business informed about it a repairing or replacement of the instrument will be arranged by us 3 How to Use the Oscilloscope The Structure of the Oscilloscope Front Panel and Keys The front panel and keys of the oscilloscope are shown in Figure 4 4 11 6 7 9 10 16 15 14 13 12 5 17 3 8 1 2 Figure 4 Fro...

Page 11: ...vious menu when the menu is the first level press the return key to close the menu 7 Measurement menu key oscilloscope or range key multimeter 8 Zoom or move key Function of direction keys used for the up and down movements of waveform the time base changing the voltage cursor movements and the trigger of electrical level change in the oscilloscope Function of direction keys used for the left and ...

Page 12: ...ey 16 Switch key for working state of oscilloscope and multimeter 17 CH1 CH2 channel switch key Side Panel 1 2 3 Description 1 Probe compensation 3 3V 1kHz square wave signal output 2 Charging or USB communication interface 3 Bracket ...

Page 13: ...g collected Ready All pre trigger data have been obtained and the oscilloscope is ready Scan Scan mode Continuously collect and display waveform data Stop Stop collecting waveform data 2 Run stop 3 Time base display 4 The pointer indicates the trigger horizontal position 5 The pointer indicates the trigger position within the current storage depth 6 Indicating the value of the current trigger hori...

Page 14: ...ter indicates the grounding reference point zero position of the waveform displayed in CH2 channel If there is no pointer indicating the channel it means that the channel is not open 16 The pointer indicates the grounding reference point zero position of the waveform displayed in CH1 channel If there is no pointer indicating the channel it means that the channel is not open 17 Waveform display are...

Page 15: ...s a square wave display 1kHz 3 3Vpp can be seen as shown in Figure 0 1 Figure 0 1 Automatic Setting Repeat steps 2 and 3 on the CH2 channel Probe Compensation When connecting the probe to any input channel for the first time make this adjustment to match the probe with the input channel The probe without compensation or deviation compensation will lead to measurement error To adjust the probe comp...

Page 16: ...Display Waveform of Probe Compensation 3 Repeat the steps if necessary Figure 0 3 Probe Adjustment Probe Attenuation Coefficient Setting The probe has a variety of attenuation coefficients which will affect the vertical position factor of the oscilloscope To change check the set value of probe attenuation coefficient in the oscilloscope menu please follow the steps below 1 Press the CH1 CH2 key to...

Page 17: ...he setting value of the probe switch is 1X and 10X See Figure 04 Figure 0 4 Probe Attenuation Switch Note When the attenuation switch is set to 1X the probe limits the bandwidth of the oscilloscope to 5 MHz To use the full bandwidth of the oscilloscope be sure to set the switch to 10X Safe Use of Probe The safety ring surrounding the probe body provides a barrier to protect the fingers from electr...

Page 18: ...ndividually for each channel Vertical position Press the CH1 CH2 keys to select the channel and move the vertical position of the selected channel up or down by pressing the or direction keys Press the and direction keys at the same time to center the vertical position Vertical Volt Div Setting The volt div range is 10mV div 10V div probe 1X stepping in the 1 2 5 way or 100mV div 100V div probe 10...

Page 19: ...hanging the horizontal scale the waveform is enlarged or reduced relative to the center of the screen When the horizontal position changes the position relative to the waveform trigger point changes Note Press the and direction keys at the same time to center the horizontal position The description of the horizontal system setting menu is as follows Function menu Setting Description Acquisition mo...

Page 20: ...ion Menu Description Automatic measurement On Off Turn automatic measurement on or off Source CH1 CH2 Set the source Add Delete Frequency F Period T Amplitude Va Maximum Ma Minimum Mi Peak to Peak value Vpp Average value V Add or delete the selected measurement type displayed in the lower left corner up to 6 types Note The unselected state is The selected state is Cursor Measurement Press and the ...

Page 21: ...ted as Time by pressing the arrow keys two cursors can be moved at the same time Trigger System The trigger determines when the oscilloscope starts to acquire data and display waveforms Once the trigger is set correctly it can convert an unstable display into a meaningful waveform When the oscilloscope starts to acquire data it first acquires enough data to draw the waveform on the left side of th...

Page 22: ...ss through Trigger type Automatic Normal Single Waveforms can be acquired without detecting trigger conditions The waveform is acquired only when the trigger conditions are met When a trigger is detected a waveform is sampled and then stopped 1 2 Enter the next menu Edge Rising edge Falling edge Trigger on the rising edge of the signal Trigger on the falling edge of the signal Trigger centered The...

Page 23: ...l memory Call Call the settings saved in the current storage location Reference Waveform The actual waveform can be compared with the reference waveform to find out the difference Press the Save key to enter the save function menu and press F2 to select the reference waveform to enter the reference waveform menu The description of the Reference Waveform menu is as follows Function Menu Setting Des...

Page 24: ...tion on the next page of system settings The description of File menu is as follows Function Menu Setting Description File Wavef orm File name weve1 weve2 weve3 weve4 Select the file name of the stored waveform Source CH1 CH2 Select the waveform channel to be saved Save Store the waveform of the source in a csv file named by the specified file name Image File name image1 image2 image3 image4 Selec...

Page 25: ...es 30 minutes 60 minutes Unlimited Set the automatic shutdown time Unlimited means no shutdown Please pay attention to this setting if you use the battery only Buzzer On Off Buzzer switch The buzzer is turned on by default in the multimeter mode 1 2 Enter the next menu About After pressing this key the instrument model serial number version and checksum can be displayed System upgrade To upgrade t...

Page 26: ...ess F2 two times to confirm the execution The factory settings are restored Automatic Correction The automatic correction program can quickly make the oscilloscope reach the best condition to obtain the most accurate measurement value You can execute this program at any time but if the ambient temperature variation range reaches or exceeds 5 you must execute this program To perform automatic corre...

Page 27: ...A mA COM and Multimeter interface 1 2 3 4 5 6 7 8 9 11 10 12 Multimeter Interface Description 1 Measurement type indication DCV DC voltage measurement ACV AC voltage measurement DCA DC current measurement ACA AC current measurement Resist Resistance measurement Diode Diode measurement ...

Page 28: ...rent reading on the display 7 Measurement value and unit 8 Display of switching resistance buzzer diode and capacitance measurement function 9 The selected range V or mV in voltage measurement the selected current range A or mA in current measurement 10 To choose AC or DC voltage measurement 11 To choose to AC or DC current measurement 12 Display of relative value measurement function only availab...

Page 29: ... Generator Output Ports To observe the output of the waveform generator connect the other end of the BNC cable to the signal input connector of the oscilloscope Set the waveform 1 Press the Mode button to switch the instrument interface to the waveform generator function interface 2 Press F1 to select the desired waveform and the screen will display the corresponding waveform setting menu 3 Set th...

Page 30: ...n the parameter column Press F2 to switch between Frequency Period Use the direction keys to change the selected parameter value Press to increase or decrease the value at the cursor Press to move the cursor left and right to different numerical digits Note When setting parameters long press the key to accelerate the change of the value Set the Amplitude High Level Press the F3 or F4 key to switch...

Page 31: ...the F3 or F4 key to switch to the Symmetry parameter use the direction keys to set the desired value in the parameter column Output the pulse waveform Press the F1 key to enter the pulse waveform setting interface The pulse waveform setting menu includes Frequency Period Start Phase Amplitude High Level Offset Low Level Pulse Width Duty Cycle Rise Time Fall Time For the setting frequency period am...

Page 32: ...ut the sine waveform on page 27 Type built in waveform The system has 8 built in waveforms To select the built in waveform Press the F3 or F4 key to switch to the Type parameter and then use the F2 or direction keys to select the desired built in waveform in the parameter column Built in waveform list Name Explanation Sinc Sinc function Bessely BesselII function Besselj BesselI function StairUp St...

Page 33: ...er 1 Connection Use a USB data cable to connect the USB Device port in the right panel of the Oscilloscope to the USB port of a PC 2 Install the driver Run the Oscilloscope communication software on PC push F1 to open the help document Follow the steps of title I Device connection in the document to install the driver 3 Port setting of the software Run the Oscilloscope software click Communication...

Page 34: ... to the multimeter the measurement type is displayed as E It may be that the measurement type was not selected At this time press F4 the measurement type should display the corresponding measurement type If E is still displayed restart the oscilloscope 4 In the oscilloscope state the measured voltage amplitude value is 10 times larger or smaller than the actual value Check whether the channel atte...

Page 35: ...ge If so center the trigger electrical level or set the trigger mode to automatic In addition you can press Auto to automatically complete the above settings 7 In the oscilloscope state the display speed becomes slower when the average value sampling is set in the acquisition mode or the duration is set longer in the display settings It is normal ...

Page 36: ...ion program see automatic correction in System Settings on P18 All specifications are guaranteed except those marked typical Oscilloscope Characteristics Description Bandwidth HDS242 S 40 MHz HDS272 S 70 MHz HDS2102 S 100 MHz Channel 2 Sampling Sampling method Sampling peak detection Real time sampling rate HDS242 S HDS272 S 125 MSa s Dual channel 250 MSa s Single channel HDS2102 S 250 MSa s Dual ...

Page 37: ...cement range 6 div Analog bandwidth HDS242 S 40 MHz HDS272 S 70 MHz HDS2102 S 100 MHz Single bandwidth Full bandwidth Low frequency response AC coupling 3dB 10 Hz Rise time typical on BNC HDS242 S 8 ns HDS272 S 5 ns HDS2102 S 3 5 ns DC gain accuracy 3 Measurement Cursor ΔV ΔT Automatic Period Frequency Mean PK PK Max Min Amplitude Trigging Source CH1 CH2 Type Edge Coupling DC AC Trigger type Auto ...

Page 38: ...age current resistance capacitance on off diode Maximum lnput voltage AC 750V DC 1000V Maximum lnput current AC 10A DC 10A Basic function Range Minimum resolution Accuracy DC voltage 200 00mV 0 01mV 0 3 10dig 2 0000V 0 1mV 0 3 5dig 20 000V 1mV 200 00V 0 01V 1000 0V 0 1V AC voltage 1 200 00mV 0 01mV 0 8 10dig 2 0000V 0 1mV 20 000V 1mV 200 00V 0 01V 750 0V 0 1V 1 10dig frequency range 40Hz 1000Hz DC...

Page 39: ... 10Ω 2 0000MΩ 0 1kΩ 20 000MΩ 1kΩ 1 3dig 100 00MΩ 0 01MΩ 5 10dig Capacitance 1 20 000nF 1pF 3 0 10dig 200 00nF 10pF 2 0000μF 0 1nF 20 000μF 1nF 200 00μF 10nF 2 0000mF 0 1uF Others On Off test 50Ω Diode test 0 2V Auto range TRMS 1 When measuring AC voltage current or capacitance accuracy guarantee range is 5 to 100 of the range Arbitrary Waveform Generator Optional Characteristics Description Wavefo...

Page 40: ...37 DC offset High Z 2 5V Amplitude Vpp 2 Frequency Resolution 0 01 Channel 1 Waveform Depth 8k Vertical Resolution 14 bit Output Impedance 50 Ω ...

Page 41: ... Ⅱ DC INPUT 5VDC 2A Power consumption 5 W Battery 2200mAh 2 3 7V 18650 Surroundings Characteristics Description Temperature Working temperature 0 40 Storage temperature 20 60 Relative humidity 90 Height Operating 3 000 meters Non operating 15 000 meters Cooling method Natural cooling Mechanical specifications Characteristics Description Dimensions 198 mm length 96mm height 38 mm width Weight About...

Page 42: ... be exposed to direct sunlight for a long time Caution Do not let spray liquid or solvent touch the instrument or probe to prevent damage to the instrument or probe Cleaning Check the instrument and probe frequently according to the operation Clean the external surface of the instrument as follows 1 Please wipe the floating dust outside the instrument and probe with a soft cloth When cleaning the ...

Page 43: ...ime it is recommended to charge it at regular intervals t o avoid over discharge of the lithium battery Battery Charging The lithium battery may not be fully charged when delivered To make the battery fully charged it takes up to 4 5 hours when the device is turned off or it is subject to the charging indicator After charging the battery can supply power for about 4 hours The power supply and batt...

Page 44: ...to the load capacity of the power supply equipment to avoid abnormal operation of the equipment Note To avoid overheating of the battery during charging the ambient temperature must not exceed the allowable value given in the technical specifications Replacement of Lithium Battery Generally the battery does not need to be replaced However when necessary it can only be replaced by qualified personn...

Reviews: