5.Front Panel Operation
24
being cut, but when the frequency, amplitude, and offset are set out of the limit range, then the
generator would use the current parameter, which leads to the recalled wave not totally the same
as the cut wave.
2.
The max data number of the waveform generator ARB is 8192. When the wave cut from
oscilloscope contains data number more than 8192, the waveform generator will compress data.
On the contrary if the data number is less than 8192, the waveform generator will use linear
interpolation.
To Save and Recall
Press
Save
function button to enter the file system.
To Use USB Storage
The storage location is divided into the internal storage (FLASH) and the USB device
storage (USBDEVICE). When a USB device is connected, the storage menu will show
"USBDEVICE" and "FLASH". Otherwise, the storage menu will show "FLASH" only.
(1)
Install the USB device
: insert a USB device into the "
⑰
USB port
" on the front panel
in
Figure 4-1
, and the screen will show "Detect USB device". Press
Save
function
button to enter the file system, the storage menu will show "USBDEVICE" and
"FLASH".
(2)
Enter the storage
: Turn the
knob
or press
/
direction key to choose the
desired storage. Press
F1
to enter the chosen storage. Provide operations as Next
level, Up one level, New folder, Delete, Rename, Copy, Paste.
(3)
Remove the USB device
: Remove the USB device from the
USB port
on the front
panel. The system will inform you "The USB device is removed", and the
"USBDEVICE" in the storage menu will disappear.
To Edit the File Name
In file system, the user can edit the name of a file or a folder. When the system needs the
user to input a name, an input keyboard will appear.
Figure 5-16: Edit the File Name