Setup
16
313221M
11.
Mount pails
a.
Insert pail handles on mounting bracket
(G).
12.
Purge air and flush fluid from lines
a.
Remove both recirculation tubes (N)
from the pails and secure each one in a
dedicated waste container (W).
b.
Set function knob to Stop/Park
.
c.
Plug in power cord(s). See T
ABLE
2,
page 13.
A
B
G
r_256765_313221_b_18
N
A
B
W
r_256765_313221_b_19
d.
Turn on Motor Power.
e.
Set Recirc/Spray valves to Recirc.
f.
Set function knob to Slow Recirc
or
Fast Recirc
.
g.
When clean fluids exit both recirculation
tubes (P), set function knob to
Stop/Park .
h.
Replace recirculation tubes in pails.
Preheat hoses if ambient temperature is
below 70°F (43.3°C) or continue with Startup,
page 18.
OR