Setup
313221M
13
Table 2: Electrical Requirements
Model
Required Power Source
Power Cord Connector
256765 - 120 V, 1 phase, 50/60 Hz,
three 15 ft (4.5 m) power cords,
Heated
Three separate, dedicated circuits
rated at minimum of 15 A each
257089 -
120 V, 1 phase, 50/60 Hz,
two 15 ft (4.5 m) power cord, Heated
Two separate, dedicated circuits
rated at minimum of 15 A each
Three NEMA 5-15T
Two NEMA 5-15T
Table 3: Extension Cord Requirements
Required Wire Size
Up to 100 ft (30 m)
AWG 12
Cords must be 3-conductor grounded, rated
for your environment.
F
IG
. 5. Use Three Separate Circuits
1
Ensure no other high amp loads are connected
while running EnergyComplete Sprayer.
To verify separate circuits, plug in
EnergyComplete Sprayer or a worklight and
cycle breakers on and off.
1
2
To avoid electric shock, always unplug all cords before ser-
vicing EnergyComplete Sprayer.
Heater Power
Motor Power
TI12383a
2
Compressor Power