OWC JUPITER CALLISTO
STORAGE CONFIGURATION
16
Inside ‘View Disks’ section, the drives are identified in a number of ways (see
Figure 4.3b
). First, each drive is assigned a device
ID by the Callisto operating system. This device ID is arbitrary and not based on the drive’s physical location inside the Callisto.
Next, each drive has a serial number. The serial number is unique to each drive and is the same as the serial number written
on the drive’s label. Third, the ‘Description’ field for each drive has been labeled with a drive bay number. This label follows
the drive; the label does not stay with the drive bay. In the event that you move a drive into another drive bay or add a new
drive, the label will need to be changed manually.
4.4 DRIVE FAILURE & REPLACEMENT
In the event of a drive failure, the Jupiter Callisto will send an alert email to the administrator (see
Section 3.2, First Time
Configuration
for information on setting the administrator email address). In order to identify the failed drive, first go to
‘Volume Status’ in the ‘Storage’ menu (
Figure 4.4a
).
Figure 4.3b
Figure 4.4a