background image

 

Mycare MP 50

4

About this instruction manual

Table of contents
1. About this instruction manual.......... 4

1.1 Symbols used................................. 5
1.2 Safety indications and dangers due 

to non-compliance.......................... 5

1.3 Units used ...................................... 5

2. Intended use ...................................... 6

2.1 Water pressure............................... 7
2.2 Information on hazard risks............ 7

3. Product description........................... 8

3.1 Intended purpose ........................... 8

4. Installation ......................................... 8

4.1 General .......................................... 8
4.2 Installation and initial putting into 

service of the point-of-use water filter

10

5. Service.............................................. 12

5.1 Commissioning............................. 12
5.2 Functional description .................. 12
5.3 Modifications / changes /

spare parts ................................... 12

5.4 Shut down .................................... 13
5.5 Replacing the cartridges .............. 13

6. Trouble shooting chart ................... 15
7. Maintenance..................................... 16

7.1 Cleaning ....................................... 16

8. Warranty and services .................... 16
9. Data sheet ........................................ 17

9.1 Type ............................................. 17
9.2 Technical data ............................. 17
9.3 Installation dimensions ................ 17

10. Spare parts  MP 50 .......................... 18
11. Customer service ............................ 20

1.

About this instruction 

manual

ATTENTION

(see  chapter  “Safety  indications  and
dangers due to non-compliance”)
The  instruction  manual  must  be  perma-
nently  available  at  the  point  of  use  of  the
Mycare filter.
The  instruction  manual  contains  important
information  on  the   Mycare      ,  so  that  it
can  be  used  in  a  safe,  economical  and
appropriate manner.
It  contains  fundamental  information,  which
must be observed during installation, opera-
tion and maintenance. Strict observance of
this  information  helps  to  avoid  danger,
reduce repair costs and increases the relia-
bility and working life of this filter.
The  instruction  manual  must  be  read  and
used by each person entrusted with carrying
out the working life of this filter, for example:
– installation
– operation

maintenance 

(servicing, inspection, repair)

Installation  and  maintenance  may  only  be
carried out by personnel authorized to do so
by  the  manufacturer,  who  are  able  to
complete the work stipulated in this installa-
tion  and  operating  manual  and  in  accord-
ance with the legal requirements valid in the
country of use.
In  addition  to  the  instructions  contained  in
this  manual,  all  valid  regulations  covering
health  and  safety  as  well  as  all  plumbing
guidelines and codes valid in the country of
use are to be adhered to at all times.
This  instruction  manual  must,  therefore,
always  be  read  by  the  installer  and  the
skilled  personnel/user  responsible,  before
the installation, prior to putting the unit into
service  or  before  performing  any  mainte-
nance on this unit.

Summary of Contents for Mycare MP50

Page 1: ...and safety information carefully before installing and putting the unit into service These must always be handed to the owner user Installation and operating instructions OWA Mycare MP50 Point of use...

Page 2: ...suitable for use in COLD water drinking applica tions up to a maximum water tempera ture of 30 C 86 F The point of use water filter operates on the basis of a 2 stage function principle 1st stage acti...

Page 3: ...transmit heat back through its respective plumbing Always ensure that this product is installed so that that the water tempe rature never exceeds a maximum of 30 C 86 F for all applications If in doub...

Page 4: ...formation on the Mycare so that it can be used in a safe economical and appropriate manner It contains fundamental information which must be observed during installation opera tion and maintenance Str...

Page 5: ...the general danger symbols given in this manual may result in the following risks among others failure of important functions of this filter danger to persons due to electrical and mechanical effects...

Page 6: ...id in the country of operation In addition to this all valid regulations governing health and safety in the country of use are to be adhered to at all times The Mycare water filter may be used only as...

Page 7: ...r the Mycare water filter is between 103 kPa 15 psi to 345 kPa 50 psi Under these pressure ranges the Mycare MP 50 water filter works most effectively 2 2 Information on hazard risks 2 2 1 Electrical...

Page 8: ...ty as close as possible to the point of use see fig 4 ATTENTION The water supply is to be turned off shut off before installation and may only be reopened once installation is fully completed Failure...

Page 9: ...he Mycare water filter can be installed in all standard commercial drinking water pipes Please shut down the incoming water supply before Installation is started Pay attention to the flow direction se...

Page 10: ...nce all the air has been vented see fig 7 7 Keep on flushing with at least 3 liters of water i e 10 minutes at rated flow or until the effluent is clear 8 Turn the faucet off 9 Set up the indicator fo...

Page 11: ...1 1 Mycare MP 50 Installation Fig 8 Installation cold water tubing tubing water filter wall mounting water filter shut off valve shut off valve brackets Shut off valves and tubing by others...

Page 12: ...icator for the next filter ch ange Move the indicator button on the flange cover to the next filter change require ment filter change every 2 6 months at the latest 7 Check for leaks both immediately...

Page 13: ...ing or the cartridge with your bare hands 10 Insert the new replacement cartridge in the built in rotary flange and press in up to the limit stop 11 Insert the filter housing into the bayonet opening...

Page 14: ...es flange cover built in rotary flange replacement cartridge micro filtration filter housing complete Allen key SW 5 used cartridge micro filtration used cartridge activated carbon bleed screw filter...

Page 15: ...rofiled flange seal is missing assembled wrongly or needs to be replaced every 2 years Check if the profiled flange seal is missing assembled wrongly or needs to be replaced The profiled side of the s...

Page 16: ...hol spiritus which may damage the unit 8 Warranty and services All products are supplied in accordance with the legal requirements of warranty legislation in their country of use Please note that fail...

Page 17: ...re min 103 kPa 15 psi Water pressure max 345 kPa 50 psi Cartridge replacement interval 3 months n i m l 2 e t a r w o l F 0 53 US gpm Total capacity per filter cartridge MF 2000 l1 528 US gal AC 2000...

Page 18: ...Mycare MP 50 8 1 Spare parts MP 50 10 Spare parts MP 50 10 1 2 4 3 B 5 6 7 8 C A A 9...

Page 19: ...2110040 B Spare parts set Filter hood consisting of pos 5 6 7 8 1 2110102 C Spare parts set Wall mounting bracket 1 2110065 2 MP 50 r e v o c e g n a l F 1 1 w e r c s d a e h t l o B 2 3 Replacement...

Page 20: ...ts are reserved for modifications as a result of technical progress or further developments Claims with regard to models or products are excluded 9990112 2015 02 OWA GmbH Postfach P O Box 100831 D 737...