THE LP-GAS CYLINDER (Propane Tank) INFORMATION:

A) Cylinder Size:  Manchester Vertical Tank #11

11 Lbs. (4kg)  Capacity: 2.6 Gallons (9.84 Liters).

B) Cylinder Size:  Manchester Tank #20

20 Lbs. (9.07kg)  Capacity: 4.6 Gallons (17.41 Liters).

BEFORE INSTALLATION, BE SURE THE LP-GAS CYLINDER/PROPANE TANKS VALVE IS CLOSED.

6. The LP-Gas Cylinder must be standing on the designed bottom base of the cylinder for proper vapor withdrawal.

When connecting the regulator to the tank valve, make sure the coupling nut does not cross-thread on the tank valve.  

Cross-threading the regulator nut to the tank valve may cause a leak.

Turn on the gas to the burner system and test for leaks with soapy water solution.

(Never use an open flame for testing)

.  If a leak is found, re-connect the regulator coupling nut and tighten until no leaks are detected.

The hose and burner should be inspected before each use of the appliance.

The hose assembly must be replaced prior to the appliance being put into operation if there is evidence of excessive abrasion or wear, or if the 

hose is damaged.  The replacement hose must be specified by the manufacturer.

Page 5

3. Make sure the appliance is NOT in use, and turn OFF the gas at the supply LP-Gas Cylinder Valve. 

4. The LP-Gas Cylinder must be disconnected when the appliance is not in use.

5. The LP-Gas Cylinders must be stored outdoors in a well-ventilated area out of the reach of children & at Least 60 inches away for 

the fire pit. Disconnected cylinders must have threaded valve caps tightly installed and must not be stored in any building, garage, 
or other enclosed area.

1.

Occasional Height Fire Pits Propane Tank Options:

            11 Pound Tank

20 Pound Horizontal Tank

2. The LP-Gas Cylinder(s) to be used must be constructed and marked in accordance with the U.S. Department of

Transportation (D.O.T.) Specifications for LP-Gas Cylinders or the Standard for Cylinders, Spheres and Tubes for Transportation 
of Dangerous Goods and Commission, CAN/CSA-B339 as applicable.
--Use cylinders approved for your area such as “Blue Rhino” or “AmeriGas” with this appliance.  Other cylinders may be 
acceptable for use with the appliance provided they can be mounted to the appliance using the cylinder retention devise provided. 
(See illustration above.)
--The LP-Gas Cylinder to be used must be provided with a listed overfilling prevention device (OPD) and with a cylinder 
connection device compatible with the connection for the appliance.

CONNECTING AN LP-GAS CYLINDER/PROPANE TANK TO THE FIRE PIT

IMPORTANT

BEFORE PROCEEDING, CAREFULLY READ ALL OF THE IMPORTANT 

SAFETY INFORMATION IN THIS OWNER'S MANUAL

A.

Important WARNINGS and Safety Information (Pages 1, 2, 3, 4)

B.

Minimum Clearance to Combustibles (Page 2)

Summary of Contents for CASUAL FIRESIDE 5110-42RDO

Page 1: ...nce is connected to a fixed gas piping supply system the installation must conform to local building codes or in the absence of local building codes to the National Fuel Gas Code ANSI Z223 1 NFPA 54 I...

Page 2: ...USE ONLY THIS UNIT MUST BE INSTALLED AT LEAST 60 FROM CENTER OF BURNER TO ANY COMBUSTIBLE WALLS CEILINGS OR MATERIAL WHEN SHUTTING OFF THE UNIT BE SURE TO TURN THE CONTROL VALVE ON THE FIRE PIT TO TH...

Page 3: ...pit and it must be closed during any pressure testing of the system at test pressures in excess of psi 3 5kPa C CHECK GAS TYPE Natural Gas or Propane The gas supply you intend to use may not be the s...

Page 4: ...r the appliance O DO NOT use this appliance if any part of it has been under water Call a qualified service technician to inspect the appliance and to replace any part of the control system and any ga...

Page 5: ...be disconnected when the appliance is not in use 5 The LP Gas Cylinders must be stored outdoors in a well ventilated area out of the reach of children at Least 60 inches away for the fire pit Disconn...

Page 6: ...ves and connections to make sure they do not leak before lighting appliance Contact with the liquid contents of the cylinder will cause freeze burns to the skin Do not allow children to tamper or play...

Page 7: ...Fire Glass Kit Size 1 2 3 4 12 20 mm 13 Mirrored Glass Kit Size 1 4 6 35mm 14 Lava Granules 3 8 15 Ceramic Rock Kit with Lava Granules 16 Ceramic Log Kit with Lava Granules PROTECTIVE SCREEN MEDIA PLA...

Page 8: ...e to expand and cause a pop and launch outside of the fire pit which could cause injury or property damage Allow lava granules to completely dry after getting wet rained on or hosed off before lightin...

Page 9: ...W MATERIAL ADEQUATE TIME TO COOL BEFORE HANDLING CAUTION Lava granules used in a fire pit are porous and when heated up to normal operating temperature can cause trapped gasses or moisture to expand a...

Page 10: ...fferent Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correct...

Page 11: ...tructions Fire Pit Component Parts O W Lee extends a two 2 year limited warranty on all burner components under normal use and proper maintenance OW Lee will at factory option repair or replace any ou...

Page 12: ...alve are off closed 2 Wait a minimum of 5 minutes for the gas to clear out OPERATING INSTRUCTIONS We recommend that before you install your Fire Pit you familiarize yourself with the control valve lay...

Page 13: ...rnia for various uses Propane itself is not a listed Proposition 65 chemical The combustion of propane in appliances such as stoves or heating systems and vehicles using propane creates harmful chemic...

Page 14: ...After The Unit Is Converted it Must Be Tested to Verify the Inlet and Manifold pressures are as specified on Page 3 Additionally a qualified service agency must verify that the input rate of the conve...

Page 15: ...les instructions fran aises INSTALLATEUR Laissez ce manuel avec l appareil CONSOMMATEUR Conservez ce manuel pour r f rence ult rieure DANGER DE MONOXYDE DE CARBONE Cet appareil peut produire du monoxy...

Page 16: ...ILISATION INCORRECTE OU UTILIS E DE VOTRE PUITS D INCENDIE EXT RIEUR PEUT CAUSER DES BLESSURES GRAVES LA MORT OU DES DOMMAGES LA PROPRI T EN CAS D INCENDIE DE BR LURES D EXPLOSIONS OU D EMPOISONNEMENT...

Page 17: ...gaz doit tre dimensionn de sorte fournir la pression minimale d admission au d bit maximum BTU hr Une perte excessive de pression se produira si le tuyau est trop petit ou trop long G Casual Fireside...

Page 18: ...llation et les r parations doivent tre effectu es par un technicien qualifi L appareil doit tre inspect avant utilisation et au moins une fois par an par un technicien qualifi Un nettoyage plus fr que...

Page 19: ...nne filet s doivent tre bien install s dans les bouteilles d connect es et ne doivent pas tre entrepos s dans un b timent un garage ou un autre espace clos 6 La bouteille de gaz GPL doit reposer sur l...

Page 20: ...z vous que la date de requalification des bouteilles est v rifi e Assurez vous que l vent du r gulateur ne pointe pas vers le haut Ne pas utiliser stocker ou transporter la bouteille dans un endroit o...

Page 21: ...ection n 10 Thermocouple 10 n 11 Granules de lave n 12 Kit de verre Pebble Taille 3 4 1 2 9 19mm n 13 Trousse de vitre coupe feu concass e Taille 1 2 3 4 12 20 mm n 14 Kit de verre miroir Taille 1 4 6...

Page 22: ...blessures ou des dommages mat riels Laissez les granules de lave s cher compl tement apr s avoir t mouill es avant de les allumer et en utilisant le foyer Page 8 PLACEMENT DE SUPPORTS EN VERRE GEM MIR...

Page 23: ...mouill es avant de les allumer et en utilisant le foyer Page 9 PLACEMENT DE SUPPORTS DE JOURNAUX EN C RAMIQUE Placement de la roche en c ramique Voir les figures 1 2 et 3 Figure 1 Versez les granules...

Page 24: ...ans le venturi et orifices des trous pour d gager le passage libre des toiles d araign es ou d autres d bris Assurez vous de tout remettre correctement lorsque vous avez termin pour le fonctionnement...

Page 25: ...ant Parties Pit Fire O W Lee offre une garantie limit e de deux 2 ans sur tous les composants du br leur en utilisation normale et appropri e entretien OW Lee sera l usine de r parer ou de remplacer t...

Page 26: ...ande du foyer et la soupape du r servoir de propane sont ferm es 2 Attendez au moins 5 minutes que le gaz se vide MODE D EMPLOI Nous vous recommandons de vous familiariser avec le sch ma de la vanne d...

Page 27: ...ue r pertori de la Proposition 65 La combustion de propane dans des appareils tels que des po les ou des syst mes de chauffage et des v hicules utilisant du propane cr e des produits chimiques nocifs...

Page 28: ...ce que les orifices d admission d air soient ferm s Figure 2 Pour le gaz propane retirez l obturateur d air de fa on ce que les orifices d admission d air soient ouverts Figure 1 Une fois que l unit e...

Reviews: