background image

Table of Contents

Cover - Important Safety Information

1

Important Safety Information and

Minimum Clearances to Combustibles

2

Pre-Installation & Preparation Guidelines

3

Important Safety Information

4

Installation Information

Connecting the Gas to the Fire Pit

5

Propane Tank Information

6

Media Placement and Replacement Parts List

Certified Media List / Protective Screen Media Clearance

7

Gem, Mirrored, Crushed Glass and Lava Rock Installation

8

Ceramic Logs and Rock Media Installation

9

Trouble Shooting Guide

10

Warranty Information

11

Operation Instructions

Lighting Instructions

12

Proposition 65 Public Warning

13

Conversion to a Different Gas Type

14

A.

B.

C.

D.

E.

OUTDOOR FIRE PIT - TABLE OF CONTENTS

IMPORTANT SAFETY INFORMATION

READ THESE INSTRUCTIONS FULLY BEFORE INSTALLING THIS OUTDOOR FIRE PIT.

If not installed and used correctly per these instructions,

this product can cause serious injury, death, and or property damage and may void the warranty.

CAUTION

:  FIXED PIPING GAS SUPPLY INSTALLATION, AND REPAIRS MUST BE DONE BY

A CERTIFIED PROFESSIONAL TECHNICIAN or LICENSED PLUMBER.

Be sure you understand all safety precautions and warnings contained in this manual.

If you have any questions, please contact O.W. Lee at (800) 776-9533

Clearances to Combustible Construction:

Sidewalls:  60”  (1.5 m) from center of unit (Figure 1)
Ceiling:  60” (1.5 m) from top of unit to ceiling or overhang
Flooring:  0” – Can be installed on deck, slab, floor, etc.

The dimensions shown in Figure 1 are MINIMUM
CLEARANCES to maintain when you install this Outdoor Fire 
Pit.  THERE MUST BE AT LEAST 60” of clearance from the 
center of the unit  to any combustible sidewalls, ceilings, or 
material.

Figure 1

Page 2

CHECK STATE AND LOCAL BUILDING CODES TO DETERMINE IF THE OUTDOOR FIRE PIT IS PERMITTED IN
YOUR LOCALITY BEFORE INSTALLATION.

FOR OUTDOOR USE ONLY.  THIS UNIT MUST BE INSTALLED AT LEAST 60” FROM CENTER OF BURNER TO ANY 
COMBUSTIBLE WALLS, CEILINGS, OR MATERIAL.

WHEN SHUTTING OFF THE UNIT — BE SURE TO TURN THE CONTROL VALVE ON THE FIRE PIT TO THE FULLY OFF 
POSITION ON THE FIRE PIT and CLOSE THE VALVE ON THE PROPANE TANK or NATURAL GAS SUPPLY LINE.

WARNING:  CARBON MONOXIDE POISONING MAY LEAD TO DEATH. 

 DO NOT MODIFY THIS OUTDOOR FIRE PIT

OR ITS CONTROLS, EXCEPT AS PROVIDED FOR IN THIS MANUAL.

IMPROPER INSTALLATION OR USE OF YOUR OUTDOOR FIRE PIT CAN CAUSE SERIOUS INJURY,  DEATH, AND OR 
PROPERTY DAMAGE FROM FIRE, BURNS, EXPLOSIONS OR CARBON MONOXIDE POISONING.

MINIMUM CLEARANCE TO COMBUSTIBLES

NOTE

MINIMUM OF 60” (1.5 m) CLEARANCE ABOVE THE 

OUTDOOR FIRE PIT IF INSTALLED UNDER CEILING OR 

OVERHANG 

60” (1.5 m)

CLEARANCE

FROM CENTER

TO ANY

COMBUSTIBLE

CONSTRUCTION

60” (1.5 m)

CLEARANCE

FROM CENTER

TO ANY 

COMBUSTIBLE

CONSTRUCTION

Summary of Contents for CASUAL FIRESIDE 5110-36RDO

Page 1: ...l and Operating Instructions in French where you can download a copy S lectionnez le lien ci dessous pour t l charger les instructions fran aises A HIGHER STANDARD IN QUALITY AND APPEARANCE SAFE AND B...

Page 2: ...nces to Combustible Construction Sidewalls 60 1 5 m from center of unit Figure 1 Ceiling 60 1 5 m from top of unit to ceiling or overhang Flooring 0 Can be installed on deck slab floor etc The dimensi...

Page 3: ...NSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS EXCEEDED F Fixed Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate BTU hr Undue...

Page 4: ...g put into operation if it is evident that the burner is damaged Replacement burner COM0595A manufactured by O W Lee Company 1822 E Francis Street Ontario CA 91761 M DO NOT store any combustible mater...

Page 5: ...o be used must be provided with a listed overfilling prevention device OPD and with a cylinder connection device compatible with the connection for the appliance 6 The LP Gas Cylinder must be standing...

Page 6: ...while dissipating Do not check for gas leaks with a match or an open flame Apply soapy water to areas marked X Open cylinder valve If bubble appears close valve and have LP gas service person make nee...

Page 7: ...all four sides as shown above Page 7 REPLACEMENT PARTS AND MEDIA ARE AVAILABLE THROUGH YOUR LOCAL DEALER 1 Stainless Steel X Burner 2 Propane Regulator 3 On Off Control Knob 4 Brass Control Valve 5 W...

Page 8: ...Outdoor Fire Pit so that the burner is covered by 1 2 and spread evenly NOTE See Page 7 For Protective Screen Media Clearance See Figure 1 and 2 Figure 1 Pour the first bag of the lava granules media...

Page 9: ...for proper air flow Note See Page 7 for Protective Screen Media Clearance CAUTION BURN HAZARD LAVA GRANULES CERAMIC LOGS and CERAMIC ROCKS WILL REMAIN HOT FOR SOME TIME AFTER USE YOU MUST MAINTAIN TH...

Page 10: ...fferent Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correct...

Page 11: ...tructions Fire Pit Component Parts O W Lee extends a two 2 year limited warranty on all burner components under normal use and proper maintenance OW Lee will at factory option repair or replace any ou...

Page 12: ...call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS STOP READ SAFETY INFORMA...

Page 13: ...various uses Propane itself is not a listed Proposition 65 chemical The combustion of propane in appliances such as stoves or heating systems and vehicles using propane creates harmful chemicals Thes...

Page 14: ...k by using a liquid soapy solution on all connections before placing the unit in operation 5 IT IS NECESSARY TO ATTACH THE LABEL OR RATING PLATE INCLUDED WITH THE CONVERSION KIT TO CLEARLY INDICATE TH...

Page 15: ...rence ult rieure DANGER DE MONOXYDE DE CARBONE Cet appareil peut produire du monoxyde de carbone qui n a pas d odeur Son utilisation dans un espace clos peut vous tuer N utilisez jamais cet appareil...

Page 16: ...ILISATION INCORRECTE OU UTILIS E DE VOTRE PUITS D INCENDIE EXT RIEUR PEUT CAUSER DES BLESSURES GRAVES LA MORT OU DES DOMMAGES LA PROPRI T EN CAS D INCENDIE DE BR LURES D EXPLOSIONS OU D EMPOISONNEMENT...

Page 17: ...rie du gaz doit tre dimensionn de sorte fournir la pression minimale d admission au d bit maximum BTU hr Une perte excessive de pression se produira si le tuyau est trop petit ou trop long G Casual Fi...

Page 18: ...llation et les r parations doivent tre effectu es par un technicien qualifi L appareil doit tre inspect avant utilisation et au moins une fois par an par un technicien qualifi Un nettoyage plus fr que...

Page 19: ...nne filet s doivent tre bien install s dans les bouteilles d connect es et ne doivent pas tre entrepos s dans un b timent un garage ou un autre espace clos 6 La bouteille de gaz GPL doit reposer sur l...

Page 20: ...z vous que la date de requalification des bouteilles est v rifi e Assurez vous que l vent du r gulateur ne pointe pas vers le haut Ne pas utiliser stocker ou transporter la bouteille dans un endroit o...

Page 21: ...DISPONIBLES CHEZ VOTRE CONCESSIONNAIRE LOCAL n 1 X Burner en acier inoxydable n 2 Tuyau de r gulateur de propane de 4 n 3 Bouton de contr le On Off marche arr t n 4 Bras De Contr le Soupape n 5 Ligne...

Page 22: ...cher compl tement apr s avoir t mouill es avant de les allumer et en utilisant le foyer PLACEMENT DE SUPPORTS EN VERRE GEM MIROIR ET BROY PLACEMENT DE SUPPORTS DE JOURNAUX EN C RAMIQUE Versez les gra...

Page 23: ...stera chaud pendant un certain temps apr s utilisation VOUS DEVEZ MAINTENIR LA DISPOSITION COMME INDIQU E POUR ASSURER LE BON FONCTIONNEMENT DE VOTRE PUITS SI VOUS DEVEZ REPOSER TOUT MAT RIAU POUR MAI...

Page 24: ...ans le venturi et orifices des trous pour d gager le passage libre des toiles d araign es ou d autres d bris Assurez vous de tout remettre correctement lorsque vous avez termin pour le fonctionnement...

Page 25: ...ant Parties Pit Fire O W Lee offre une garantie limit e de deux 2 ans sur tous les composants du br leur en utilisation normale et appropri e entretien OW Lee sera l usine de r parer ou de remplacer t...

Page 26: ...ande du foyer et la soupape du r servoir de propane sont ferm es 2 Attendez au moins 5 minutes que le gaz se vide MODE D EMPLOI Nous vous recommandons de vous familiariser avec le sch ma de la vanne d...

Page 27: ...ue r pertori de la Proposition 65 La combustion de propane dans des appareils tels que des po les ou des syst mes de chauffage et des v hicules utilisant du propane cr e des produits chimiques nocifs...

Page 28: ...ce que les orifices d admission d air soient ferm s Figure 2 Pour le gaz propane retirez l obturateur d air de fa on ce que les orifices d admission d air soient ouverts Figure 1 Une fois que l unit e...

Reviews: