background image

IMPORTANT SAFETY INFORMATION 

Pre-Installation & Preparation Guidelines

A. Before installing the Outdoor Fire Pit, check “Minimum Clearance to Combustibles” on page 2.

MINIMUM CLEARANCES

 must be maintained when you install this Outdoor Fire Pit.  

THERE  MUST

BE AT LEAST 60”

 (1.5 m) from the center of the burner to any combustible sidewall, ceiling, or material.  

B. The Outdoor Fire Pit is for outdoor use only.  DO NOT install or use this appliance inside a building,

garage, or any other enclosed area or structure including recreational vehicles, boats & sheds.  

This unit must be

installed in such a manner that proper air ventilation is maintained without obstruction at all times, and during all 
weather conditions. 

C.

CHECK GAS TYPE

 (Natural Gas or Propane):  The gas supply you intend to use may not be the same that your fire pit was 

setup for or is stated on your outdoor rating plate.  

THIS FIRE PIT IS CONSTRUCTED FOR USE WITH PROPANE

 

GAS

.  If 

the gas supply is different, 

or you wish to change to Natural Gas, you MUST have the Fire Pit Converted (directions to 

convert can be found on page 14) to the gas type you intend to use.  Any gas type conversion should be performed 
by a qualified, professional technician or licensed plumber

.  If you are unsure, contact your dealer for assistance.

D.

DO NOT USE IF GAS PRESSURE IS LOWER THAN THE MINIMUM REQUIREMENT OR EXCEEDS THE MAXIMUM.

E.

GAS PRESSURE REQUIREMENTS:  FOR NATURAL GAS:

The minimum inlet gas supply pressure for purposes of input adjustment is

 3.5 inches

 (127 mm) water column and maximum 

inlet gas supply pressure is 

10 inches

 (254 mm) water column.

FOR PROPANE: 

 The minimum inlet gas supply pressure for purposes of input adjustment is 

8 inches

(203 mm) water column and the maximum inlet gas supply pressure is 

13 inches

 (330 mm) water column.

MANIFOLD PRESSURE REQUIREMENT

:   Liquid Propane 9.5 (241.3mm)  / Natural Gas 2.5 (63.5mm) of pressure.

DO NOT INSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS EXCEEDED.

F. Fixed Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate (BTU/hr).  Undue 

pressure loss will occur if the pipe is too small or the run is too long.

G. Casual Fireside Fire Pits are suitable for installation from 0 - 4,500 ft. elevation without modification.

H. If the Outdoor Fire Pit is connected to a fixed piping gas supply line, the supply line is required to have an on/off gas valve 

installed before the fire pit and it must be closed during any pressure testing of the system at test pressures in excess of ½ 
psi (3.5kPa).  

I. If the Outdoor Fire Pit is connected to a fixed piping gas supply line, the supply line is required to have an on/off gas valve 

installed before the fire pit and must be closed during any pressure testing of the system at test pressures equal to or less 
than ½ psi (3.5kPa).

J.

INSTALLER NOTE:  This unit should be installed so that it can be removed at a later date for service.

K.

GAS SUPPLY PLUMBING REQUIREMENTS 

Apply only joint compounds that are resistant to all gasses on all male pipe fittings.  Make sure to tighten every joint securely.  

DO NOT use pipe joint compound to connect flare fittings

.

O.

SAFETY NOTE:  

Fire pits connected to a fixed piped gas line, require a second gas shut off valve.  The valve must be kept in 

the off position when the fire pit is not in use.  The secondary valve shuts off the gas supply to the fire pit,  and allows for 
maintenance and repair.

Page 3

L.

Propane Regulator Hose:

  Always inspect the condition of the propane regulator hose before each operation.  Any signs of 

excessive abrasion the hose MUST BE REPLACED.  Contact your local dealer for replacement part #COM0589

M.

Propane Regulator Hose 

(when used):   The propane regulator hose is located inside the fire pit door panel.  When 

installed, make sure the hose is secured inside the unit and 

DOES NOT TOUCH THE BURNER PAN.

N.

Note:  The Use Of A Third Party Fire Pit Top, Media and or Components Will Void the LABTEST Certification
and O.W Lee Warranty. 

Summary of Contents for CASUAL FIRESIDE 5110-36RDO

Page 1: ...l and Operating Instructions in French where you can download a copy S lectionnez le lien ci dessous pour t l charger les instructions fran aises A HIGHER STANDARD IN QUALITY AND APPEARANCE SAFE AND B...

Page 2: ...nces to Combustible Construction Sidewalls 60 1 5 m from center of unit Figure 1 Ceiling 60 1 5 m from top of unit to ceiling or overhang Flooring 0 Can be installed on deck slab floor etc The dimensi...

Page 3: ...NSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS EXCEEDED F Fixed Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate BTU hr Undue...

Page 4: ...g put into operation if it is evident that the burner is damaged Replacement burner COM0595A manufactured by O W Lee Company 1822 E Francis Street Ontario CA 91761 M DO NOT store any combustible mater...

Page 5: ...o be used must be provided with a listed overfilling prevention device OPD and with a cylinder connection device compatible with the connection for the appliance 6 The LP Gas Cylinder must be standing...

Page 6: ...while dissipating Do not check for gas leaks with a match or an open flame Apply soapy water to areas marked X Open cylinder valve If bubble appears close valve and have LP gas service person make nee...

Page 7: ...all four sides as shown above Page 7 REPLACEMENT PARTS AND MEDIA ARE AVAILABLE THROUGH YOUR LOCAL DEALER 1 Stainless Steel X Burner 2 Propane Regulator 3 On Off Control Knob 4 Brass Control Valve 5 W...

Page 8: ...Outdoor Fire Pit so that the burner is covered by 1 2 and spread evenly NOTE See Page 7 For Protective Screen Media Clearance See Figure 1 and 2 Figure 1 Pour the first bag of the lava granules media...

Page 9: ...for proper air flow Note See Page 7 for Protective Screen Media Clearance CAUTION BURN HAZARD LAVA GRANULES CERAMIC LOGS and CERAMIC ROCKS WILL REMAIN HOT FOR SOME TIME AFTER USE YOU MUST MAINTAIN TH...

Page 10: ...fferent Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correct...

Page 11: ...tructions Fire Pit Component Parts O W Lee extends a two 2 year limited warranty on all burner components under normal use and proper maintenance OW Lee will at factory option repair or replace any ou...

Page 12: ...call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS STOP READ SAFETY INFORMA...

Page 13: ...various uses Propane itself is not a listed Proposition 65 chemical The combustion of propane in appliances such as stoves or heating systems and vehicles using propane creates harmful chemicals Thes...

Page 14: ...k by using a liquid soapy solution on all connections before placing the unit in operation 5 IT IS NECESSARY TO ATTACH THE LABEL OR RATING PLATE INCLUDED WITH THE CONVERSION KIT TO CLEARLY INDICATE TH...

Page 15: ...rence ult rieure DANGER DE MONOXYDE DE CARBONE Cet appareil peut produire du monoxyde de carbone qui n a pas d odeur Son utilisation dans un espace clos peut vous tuer N utilisez jamais cet appareil...

Page 16: ...ILISATION INCORRECTE OU UTILIS E DE VOTRE PUITS D INCENDIE EXT RIEUR PEUT CAUSER DES BLESSURES GRAVES LA MORT OU DES DOMMAGES LA PROPRI T EN CAS D INCENDIE DE BR LURES D EXPLOSIONS OU D EMPOISONNEMENT...

Page 17: ...rie du gaz doit tre dimensionn de sorte fournir la pression minimale d admission au d bit maximum BTU hr Une perte excessive de pression se produira si le tuyau est trop petit ou trop long G Casual Fi...

Page 18: ...llation et les r parations doivent tre effectu es par un technicien qualifi L appareil doit tre inspect avant utilisation et au moins une fois par an par un technicien qualifi Un nettoyage plus fr que...

Page 19: ...nne filet s doivent tre bien install s dans les bouteilles d connect es et ne doivent pas tre entrepos s dans un b timent un garage ou un autre espace clos 6 La bouteille de gaz GPL doit reposer sur l...

Page 20: ...z vous que la date de requalification des bouteilles est v rifi e Assurez vous que l vent du r gulateur ne pointe pas vers le haut Ne pas utiliser stocker ou transporter la bouteille dans un endroit o...

Page 21: ...DISPONIBLES CHEZ VOTRE CONCESSIONNAIRE LOCAL n 1 X Burner en acier inoxydable n 2 Tuyau de r gulateur de propane de 4 n 3 Bouton de contr le On Off marche arr t n 4 Bras De Contr le Soupape n 5 Ligne...

Page 22: ...cher compl tement apr s avoir t mouill es avant de les allumer et en utilisant le foyer PLACEMENT DE SUPPORTS EN VERRE GEM MIROIR ET BROY PLACEMENT DE SUPPORTS DE JOURNAUX EN C RAMIQUE Versez les gra...

Page 23: ...stera chaud pendant un certain temps apr s utilisation VOUS DEVEZ MAINTENIR LA DISPOSITION COMME INDIQU E POUR ASSURER LE BON FONCTIONNEMENT DE VOTRE PUITS SI VOUS DEVEZ REPOSER TOUT MAT RIAU POUR MAI...

Page 24: ...ans le venturi et orifices des trous pour d gager le passage libre des toiles d araign es ou d autres d bris Assurez vous de tout remettre correctement lorsque vous avez termin pour le fonctionnement...

Page 25: ...ant Parties Pit Fire O W Lee offre une garantie limit e de deux 2 ans sur tous les composants du br leur en utilisation normale et appropri e entretien OW Lee sera l usine de r parer ou de remplacer t...

Page 26: ...ande du foyer et la soupape du r servoir de propane sont ferm es 2 Attendez au moins 5 minutes que le gaz se vide MODE D EMPLOI Nous vous recommandons de vous familiariser avec le sch ma de la vanne d...

Page 27: ...ue r pertori de la Proposition 65 La combustion de propane dans des appareils tels que des po les ou des syst mes de chauffage et des v hicules utilisant du propane cr e des produits chimiques nocifs...

Page 28: ...ce que les orifices d admission d air soient ferm s Figure 2 Pour le gaz propane retirez l obturateur d air de fa on ce que les orifices d admission d air soient ouverts Figure 1 Une fois que l unit e...

Reviews: