SAFETY NOTE:  

Fire pits connected to a fixed piped gas line, require a second gas shut off valve.  The valve must be kept in 

the off position when the fire pit is not in use.  The secondary valve shuts off the gas supply to the fire pit,  and allows for 
maintenance and repair.

Page 3

L.

Propane Regulator Hose:

  Always inspect the condition of the propane regulator hose before each operation.  Any signs of 

excessive abrasion the hose MUST BE REPLACED.  Contact your local dealer for replacement part #COM0589

M.

Propane Regulator Hose 

(when used):   The propane regulator hose is located inside the fire pit door panel.  When 

installed, make sure the hose is secured inside the unit and 

DOES NOT TOUCH THE BURNER PAN.

N.

Note:  The Use Of A Third Party Fire Pit Top, Media and or Components Will Void the LABTEST Certification
and O.W Lee Warranty. 

I. If the Outdoor Fire Pit is connected to a fixed piping gas supply line, the supply line is required to have an on/off gas valve 

installed before the fire pit and must be closed during any pressure testing of the system at test pressures equal to or less 
than ½ psi (3.5kPa).

J.

INSTALLER NOTE:  This unit should be installed so that it can be removed at a later date for service.

K.

GAS SUPPLY PLUMBING REQUIREMENTS 

Apply only joint compounds that are resistant to all gasses on all male pipe fittings.  Make sure to tighten every joint securely.  

DO NOT use pipe joint compound to connect flare fittings

.

F. Fixed Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate (BTU/hr).  Undue 

pressure loss will occur if the pipe is too small or the run is too long.

G. Casual Fireside Fire Pits are suitable for installation from 0 - 4,500 ft. elevation without modification.

H. If the Outdoor Fire Pit is connected to a fixed piping gas supply line, the supply line is required to have an on/off gas valve 

installed before the fire pit and it must be closed during any pressure testing of the system at test pressures in excess of ½ 
psi (3.5kPa).  

C.

CHECK GAS TYPE

 (Natural Gas or Propane):  The gas supply you intend to use may not be the same that your fire pit was 

setup for or is stated on your outdoor rating plate.  

THIS FIRE PIT IS CONSTRUCTED FOR USE WITH PROPANE

 

GAS

.  If 

the gas supply is different, 

or you wish to change to Natural Gas, you MUST have the Fire Pit Converted (directions to 

convert can be found on page 14) to the gas type you intend to use.  Any gas type conversion should be performed 
by a qualified, professional technician or licensed plumber

.  If you are unsure, contact your dealer for assistance.

D.

DO NOT USE IF GAS PRESSURE IS LOWER THAN THE MINIMUM REQUIREMENT OR EXCEEDS THE MAXIMUM.

E.

GAS PRESSURE REQUIREMENTS:  FOR NATURAL GAS:

The minimum inlet gas supply pressure for purposes of input adjustment is

 3.5 inches

 (127 mm) water column and maximum 

inlet gas supply pressure is 

10 inches

 (254 mm) water column.

FOR PROPANE: 

 The minimum inlet gas supply pressure for purposes of input adjustment is 

8 inches

(203 mm) water column and the maximum inlet gas supply pressure is 

13 inches

 (330 mm) water column.

MANIFOLD PRESSURE REQUIREMENT

:   Liquid Propane 9.5 (241.3mm)  / Natural Gas 2.5 (63.5mm) of pressure.

DO NOT INSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS EXCEEDED.

IMPORTANT SAFETY INFORMATION 

Pre-Installation & Preparation Guidelines

A. Before installing the Outdoor Fire Pit, check “Minimum Clearance to Combustibles” on page 2.

MINIMUM CLEARANCES

 must be maintained when you install this Outdoor Fire Pit.  

THERE  MUST

BE AT LEAST 60”

 (1.5 m) from the center of the burner to any combustible sidewall, ceiling, or material.  

B. The Outdoor Fire Pit is for outdoor use only.  DO NOT install or use this appliance inside a building,

garage, or any other enclosed area or structure including recreational vehicles, boats & sheds.  

This unit must be

installed in such a manner that proper air ventilation is maintained without obstruction at all times, and during all 
weather conditions. 

Summary of Contents for CASUAL FIRESIDE 5110-30RDC-E

Page 1: ...0 Natural Gas BUILDING CODE AND FIXED PIPING SUPPLY REQUIREMENTS When an appliance is connected to a fixed gas piping supply system the installation must conform to local building codes or in the abse...

Page 2: ...ALLATION FOR OUTDOOR USE ONLY THIS UNIT MUST BE INSTALLED AT LEAST 60 FROM CENTER OF BURNER TO ANY COMBUSTIBLE WALLS CEILINGS OR MATERIAL WHEN SHUTTING OFF THE UNIT BE SURE TO TURN THE CONTROL VALVE O...

Page 3: ...pit and it must be closed during any pressure testing of the system at test pressures in excess of psi 3 5kPa C CHECK GAS TYPE Natural Gas or Propane The gas supply you intend to use may not be the s...

Page 4: ...r the appliance O DO NOT use this appliance if any part of it has been under water Call a qualified service technician to inspect the appliance and to replace any part of the control system and any ga...

Page 5: ...ing put into operation if there is evidence of excessive abrasion or wear or if the hose is damaged The replacement hose must be specified by the manufacturer Page 5 1 2 The LP Gas Cylinder s to be us...

Page 6: ...ves and connections to make sure they do not leak before lighting appliance Contact with the liquid contents of the cylinder will cause freeze burns to the skin Do not allow children to tamper or play...

Page 7: ...22 6 Brass Fitting 7 Propane Orifice 8 Natural Gas Conversion Kit 9 Protective Mesh Screen 10 Thermocouple 11 Electronic Igniter 12 Spark Electrode 13 Pebble Glass Kit Size 3 4 1 2 9 19mm 14 Crushed F...

Page 8: ...e to expand and cause a pop and launch outside of the fire pit which could cause injury or property damage Allow lava granules to completely dry after getting wet rained on or hosed off before lightin...

Page 9: ...W MATERIAL ADEQUATE TIME TO COOL BEFORE HANDLING CAUTION Lava granules used in a fire pit are porous and when heated up to normal operating temperature can cause trapped gasses or moisture to expand a...

Page 10: ...ferent Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correctl...

Page 11: ...ions Fire Pit Component Parts O W Lee extends a two 2 year limited warranty on all burner components under normal use and proper maintenance OW Lee will at factory option repair or replace any outdoor...

Page 12: ...tank valve is closed 2 Wait a minimum of 5 minutes for the gas to clear out OPERATING INSTRUCTIONS We recommend that before you install your Fire Pit you familiarize yourself with the control valve l...

Page 13: ...for various uses Propane itself is not a listed Proposition 65 chemical The combustion of propane in appliances such as stoves or heating systems and vehicles using propane creates harmful chemicals...

Page 14: ...nd replace it with the proper sized one for your gas requirement Propane requires the smaller orifice 4 If you are converting from propane LP gas to natural gas install the air shutter sleeve so that...

Page 15: ...de carbone qui n a pas d odeur Son utilisation dans un espace clos peut vous tuer N utilisez jamais cet appareil dans un espace clos tel qu une caravane une tente une voiture ou la maison 4 Apr s avoi...

Page 16: ...LEMENT CET APPAREIL DOIT TRE INSTALL AU MOINS 60 PO DU CENTRE DU BR LEUR TOUT MURS PLAFONDS OU MAT RIAUX COMBUSTIBLES LORSQUE VOUS TEIGNEZ L APPAREIL VEILLEZ COMMANDER LA VANNE DE CONTR LE DU PUITS D...

Page 17: ...az doit tre dimensionn de sorte fournir la pression minimale d admission au d bit maximum BTU hr Une perte excessive de pression se produira si le tuyau est trop petit ou trop long G Casual Fireside f...

Page 18: ...llation et les r parations doivent tre effectu es par un technicien qualifi L appareil doit tre inspect avant utilisation et au moins une fois par an par un technicien qualifi Un nettoyage plus fr que...

Page 19: ...usure excessive ou si le tuyau est endommag Le tuyau de remplacement doit tre sp cifi par le fabricant 1 2 La ou les bouteilles de gaz LP utiliser doivent tre construites et marqu es conform ment aux...

Page 20: ...z vous que la date de requalification des bouteilles est v rifi e Assurez vous que l vent du r gulateur ne pointe pas vers le haut Ne pas utiliser stocker ou transporter la bouteille dans un endroit o...

Page 21: ...ontr le Soupape n 5 Ligne Flex 22 Chuchotement Silencieux n 6 Connecteur de bouteille de propane n 7 Orifice de propane n 8 Kit de conversion de gaz propane en gaz naturel n 9 cran de protection n 10...

Page 22: ...ra chaud pendant un certain temps apr s utilisation VOUS DEVEZ MAINTENIR LA DISPOSITION COMME INDIQU E POUR ASSURER LE BON FONCTIONNEMENT DE VOTRE PUITS SI VOUS DEVEZ REPOSER TOUT MAT RIAU POUR MAINTE...

Page 23: ...LA DISPOSITION APPROPRI E UTILISEZ LA CHALEUR GANTS R SISTANTS OU PERMETTRE AU MAT RIEL UN TEMPS APPROPRI DE SE REFROIDIR AVANT MANIPULATION ATTENTION les granules de lave utilis es dans un foyer sont...

Page 24: ...ans le venturi et orifices des trous pour d gager le passage libre des toiles d araign es ou d autres d bris Assurez vous de tout remettre correctement lorsque vous avez termin pour le fonctionnement...

Page 25: ...ant Parties Pit Fire O W Lee offre une garantie limit e de deux 2 ans sur tous les composants du br leur en utilisation normale et appropri e entretien OW Lee sera l usine de r parer ou de remplacer t...

Page 26: ...ontr le du foyer ainsi que la vanne du r servoir de propane sont ferm es 2 Attendez au moins 5 minutes que le gaz se vide MODE D EMPLOI Nous vous recommandons de vous familiariser avec le sch ma de la...

Page 27: ...ue r pertori de la Proposition 65 La combustion de propane dans des appareils tels que des po les ou des syst mes de chauffage et des v hicules utilisant du propane cr e des produits chimiques nocifs...

Page 28: ...ce que les orifices d admission d air soient ferm s Figure 2 Pour le gaz propane retirez l obturateur d air de fa on ce que les orifices d admission d air soient ouverts Figure 1 Une fois que l unit e...

Reviews: