THE LP-GAS CYLINDER (Propane Tank) INFORMATION:

A) Cylinder Size:  Manchester Vertical Tank #11

11 Lbs. (4kg)  Capacity: 2.6 Gallons (9.84 Liters).

B) Cylinder Size:  Manchester Tank #20

20 Pound Horizontal Tank

20 Lbs. (9.07kg)  Capacity: 4.6 Gallons (17.41 Liters).

BEFORE INSTALLATION, BE SURE THE LP-GAS CYLINDER/PROPANE TANKS VALVE IS CLOSED.

IMPORTANT

BEFORE PROCEEDING, CAREFULLY READ ALL OF THE IMPORTANT 

SAFETY INFORMATION IN THIS OWNER'S MANUAL

Occasional Height Fire Pits Propane Tank Options:

CONNECTING AN LP-GAS CYLINDER/PROPANE TANK TO THE FIRE PIT

When connecting the regulator to the tank valve, make sure the coupling nut does not cross-thread on the tank valve.  

Cross-threading the regulator nut to the tank valve may cause a leak.

Turn on the gas to the burner system and test for leaks with soapy water solution.

(Never use an open flame for testing).  If a leak is found, re-connect the regulator coupling nut and tighten until no leaks are detected.

The hose and burner should be inspected before each use of the appliance.

The hose assembly must be replaced prior to the appliance being put into operation if there is evidence of excessive abrasion or wear, 

or if the hose is damaged.  The replacement hose must be specified by the manufacturer.

The LP-Gas Cylinders must be stored outdoors in a well-ventilated area out of the reach of children & at Least 60 inches away for 
the fire pit. Disconnected cylinders must have threaded valve caps tightly installed and must not be stored in any building, garage, 
or other enclosed area.

3. Make sure the appliance is NOT in use, and turn OFF the gas at the supply LP-Gas Cylinder Valve. 

The LP-Gas Cylinder must be disconnected when the appliance is not in use.

Important WARNINGS and Safety Information (Pages 1, 2, 3, 4)

6. The LP-Gas Cylinder must be standing on the designed bottom base of the cylinder for proper vapor withdrawal.

A.

11 Pound Tank

1.

4.

5.

Page 5

B.

Minimum Clearance to Combustibles (Page 2)

The LP-Gas Cylinder(s) to be used must be constructed and marked in accordance with the U.S. Department of
Transportation (D.O.T.) Specifications for LP-Gas Cylinders or the Standard for Cylinders, Spheres and Tubes for Transportation 
of Dangerous Goods and Commission, CAN/CSA-B339 as applicable.
--Use cylinders approved for your area such as “Blue Rhino” or “AmeriGas” with this appliance.  Other cylinders may be 
acceptable for use with the appliance provided they can be mounted to the appliance using the cylinder retention devise provided. 
(See illustration above.)
--The LP-Gas Cylinder to be used must be provided with a listed overfilling prevention device (OPD) and with a cylinder 
connection device compatible with the connection for the appliance.

2.

Summary of Contents for CASUAL FIRESIDE 5110-3050O-E

Page 1: ...ply system the installation must conform to local building codes or in the absence of local building codes to the National Fuel Gas Code ANSI Z223 1 NFPA 54 International Fuel Gas Code Natural Gas and...

Page 2: ...FOR OUTDOOR USE ONLY THIS UNIT MUST BE INSTALLED AT LEAST 60 FROM CENTER OF BURNER TO ANY COMBUSTIBLE WALLS CEILINGS OR MATERIAL WHEN SHUTTING OFF THE UNIT BE SURE TO TURN THE CONTROL VALVE ON THE FIR...

Page 3: ...pit and it must be closed during any pressure testing of the system at test pressures in excess of psi 3 5kPa C CHECK GAS TYPE Natural Gas or Propane The gas supply you intend to use may not be the s...

Page 4: ...near the appliance O DO NOT use this appliance if any part of it has been under water Call a qualified service technician to inspect the appliance and to replace any part of the control system and any...

Page 5: ...e LP Gas Cylinders must be stored outdoors in a well ventilated area out of the reach of children at Least 60 inches away for the fire pit Disconnected cylinders must have threaded valve caps tightly...

Page 6: ...ves and connections to make sure they do not leak before lighting appliance Contact with the liquid contents of the cylinder will cause freeze burns to the skin Do not allow children to tamper or play...

Page 7: ...er Quiet Flex Line 22 6 Brass Fitting 7 Propane Orifice 8 Natural Gas Conversion Kit 9 Protective Mesh Screen 10 Thermocouple 11 Electronic Igniter 12 Spark Electrode 13 Pebble Glass Kit Size 3 4 1 2...

Page 8: ...e to expand and cause a pop and launch outside of the fire pit which could cause injury or property damage Allow lava granules to completely dry after getting wet rained on or hosed off before lightin...

Page 9: ...ME AFTER USE YOU MUST MAINTAIN THE LAYOUT AS SHOWN TO ENSURE PROPER OPERATION OF YOUR FIRE PIT IF YOU NEED TO REPOSITION ANY MATERIAL TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW M...

Page 10: ...ferent Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correctl...

Page 11: ...ions Fire Pit Component Parts O W Lee extends a two 2 year limited warranty on all burner components under normal use and proper maintenance OW Lee will at factory option repair or replace any outdoor...

Page 12: ...tank valve is closed 2 Wait a minimum of 5 minutes for the gas to clear out OPERATING INSTRUCTIONS We recommend that before you install your Fire Pit you familiarize yourself with the control valve l...

Page 13: ...for various uses Propane itself is not a listed Proposition 65 chemical The combustion of propane in appliances such as stoves or heating systems and vehicles using propane creates harmful chemicals...

Page 14: ...nd replace it with the proper sized one for your gas requirement Propane requires the smaller orifice 4 If you are converting from propane LP gas to natural gas install the air shutter sleeve so that...

Page 15: ...n espace clos tel qu une caravane une tente une voiture ou la maison 4 Apr s avoir quitt les lieux appelez votre fournisseur de gaz ou le service d incendie DANGER Cet appareil gaz est con u comme un...

Page 16: ...AU MOINS 60 PO DU CENTRE DU BR LEUR TOUT MURS PLAFONDS OU MAT RIAUX COMBUSTIBLES LORSQUE VOUS TEIGNEZ L APPAREIL VEILLEZ COMMANDER LA VANNE DE CONTR LE DU PUITS D INCENDIE LA POSITION TOTALE DE L ALLU...

Page 17: ...rie du gaz doit tre dimensionn de sorte fournir la pression minimale d admission au d bit maximum BTU hr Une perte excessive de pression se produira si le tuyau est trop petit ou trop long G Casual Fi...

Page 18: ...nstallation et les r parations doivent tre effectu es par un technicien qualifi L appareil doit tre inspect avant utilisation et au moins une fois par an par un technicien qualifi Un nettoyage plus fr...

Page 19: ...e gaz GPL doit reposer sur la base inf rieure de la bouteille con ue pour permettre un retrait appropri de la vapeur 1 2 La ou les bouteilles de gaz LP utiliser doivent tre construites et marqu es con...

Page 20: ...z vous que la date de requalification des bouteilles est v rifi e Assurez vous que l vent du r gulateur ne pointe pas vers le haut Ne pas utiliser stocker ou transporter la bouteille dans un endroit o...

Page 21: ...arche arr t n 4 Bras De Contr le Soupape n 5 Ligne Flex 22 Chuchotement Silencieux n 6 Connecteur de bouteille de propane n 7 Orifice de propane n 8 Kit de conversion de gaz propane en gaz naturel n 9...

Page 22: ...tera chaud pendant un certain temps apr s utilisation VOUS DEVEZ MAINTENIR LA DISPOSITION COMME INDIQU E POUR ASSURER LE BON FONCTIONNEMENT DE VOTRE PUITS SI VOUS DEVEZ REPOSER TOUT MAT RIAU POUR MAIN...

Page 23: ...provoquer une expansion des gaz pi g s ou de l humidit et provoquer un clatement et un lancement pourrait causer des blessures ou des dommages mat riels Laissez les granules de lave s cher compl temen...

Page 24: ...ans le venturi et orifices des trous pour d gager le passage libre des toiles d araign es ou d autres d bris Assurez vous de tout remettre correctement lorsque vous avez termin pour le fonctionnement...

Page 25: ...ant Parties Pit Fire O W Lee offre une garantie limit e de deux 2 ans sur tous les composants du br leur en utilisation normale et appropri e entretien OW Lee sera l usine de r parer ou de remplacer t...

Page 26: ...ontr le du foyer ainsi que la vanne du r servoir de propane sont ferm es 2 Attendez au moins 5 minutes que le gaz se vide MODE D EMPLOI Nous vous recommandons de vous familiariser avec le sch ma de la...

Page 27: ...ue r pertori de la Proposition 65 La combustion de propane dans des appareils tels que des po les ou des syst mes de chauffage et des v hicules utilisant du propane cr e des produits chimiques nocifs...

Page 28: ...ce que les orifices d admission d air soient ferm s Figure 2 Pour le gaz propane retirez l obturateur d air de fa on ce que les orifices d admission d air soient ouverts Figure 1 Une fois que l unit e...

Reviews: