OW Lee CASUAL FIRESIDE 5110-3050O-E Owner'S Manual Download Page 14

Date
Serial Number

Model #

COM0580

Work Order #

Orifice Installed 

#40 - Liquid Propane

BTU Rating

Orifice Included

NG #31 COM0580CK

Inspector

Air Shutter Sleeve

Included

Leak Test

Gas Type

Liquid Propane

Burn Test

LP 60,000 / NG 62,500

Page 14

FIGURE 1

Casual Fireside Fire Pits Are
Suitable For Installation from

0 - 4,500 ft. Without Modification.

Follow steps 1 – 5 shown above.
THE CONVERSION MUST BE CARRIED OUT 
BY A QUALIFIED SERVICE AGENCY, IN 
ACCORDANCE WITH THE REQUIREMENTS OF 
THE  MANUFACTURER, PROVINCIAL OR 
TERRITORIAL AUTHORITIES HAVING 
JURISDICTION AND IN ACCORDANCE WITH 
THE REQUIREMENTS OF THE CAN/CGA-
B149.1 OR CAN/CGA-B149.2
INSTALLATION CODES.

After conversion follow Operating Instructions 
found on Page 12.

FIGURE 2

After The Unit Is Converted, it Must Be 
Tested to Verify the Inlet and Manifold 
pressures are as specified on Page 3.  
Additionally, a qualified

 

service agency must 

verify that the input rate of the converted 
appliance match the rating listed below.

MANUFACTURER'S USE ONLY

QUALITY CHECK

3.

Remove the orifice from the holder (Figure # 2 ) and replace it with the proper sized one for your gas requirement.  
Propane requires the smaller orifice.  

4.

If you are converting from propane (LP) gas to natural gas, install the air shutter sleeve so that the air intake holes are 
closed (Figure #2). For Propane gas, remove the air shutter so that the air intake holes are open (Figure #1).  After the 
unit is assembled for use, you are required to do a "leak check" by using a liquid 

soapy

 solution on all connections 

before placing the unit in operation.

5.

IT IS NECESSARY TO ATTACH THE LABEL OR RATING PLATE INCLUDED WITH THE CONVERSION KIT TO 
CLEARLY INDICATE THE FIELD CONVERSION. 

CONVERTING YOUR FIRE PIT TO NATURAL GAS

This Conversion should only be performed by a Qualified Service Technician or Licensed Plumbe

1.

MAKE SURE THAT THE GAS SUPPLY TO THE FIRE PIT (AND ANY NEARBY ELECTRICAL 
SOURCES/APPLIANCES) ARE SHUT OFF.

2.

Carefully detach the flex line connector hose attached to the orifice holder (Figure # 1) and unscrew the orifice holder 
from the burner pipe (Figures #1 and # 2).

Orifice

Orifice Holder

Burner

When converting to natural gas, the air shutter 
sleeve MUST be installed over the burner pipe.

Flex Line

Connector Hose

Burner

Orifice Holder

Flex Line

Connector Hose

Orifice

Air Intake hole open for LP Gas

Summary of Contents for CASUAL FIRESIDE 5110-3050O-E

Page 1: ...ply system the installation must conform to local building codes or in the absence of local building codes to the National Fuel Gas Code ANSI Z223 1 NFPA 54 International Fuel Gas Code Natural Gas and...

Page 2: ...FOR OUTDOOR USE ONLY THIS UNIT MUST BE INSTALLED AT LEAST 60 FROM CENTER OF BURNER TO ANY COMBUSTIBLE WALLS CEILINGS OR MATERIAL WHEN SHUTTING OFF THE UNIT BE SURE TO TURN THE CONTROL VALVE ON THE FIR...

Page 3: ...pit and it must be closed during any pressure testing of the system at test pressures in excess of psi 3 5kPa C CHECK GAS TYPE Natural Gas or Propane The gas supply you intend to use may not be the s...

Page 4: ...near the appliance O DO NOT use this appliance if any part of it has been under water Call a qualified service technician to inspect the appliance and to replace any part of the control system and any...

Page 5: ...e LP Gas Cylinders must be stored outdoors in a well ventilated area out of the reach of children at Least 60 inches away for the fire pit Disconnected cylinders must have threaded valve caps tightly...

Page 6: ...ves and connections to make sure they do not leak before lighting appliance Contact with the liquid contents of the cylinder will cause freeze burns to the skin Do not allow children to tamper or play...

Page 7: ...er Quiet Flex Line 22 6 Brass Fitting 7 Propane Orifice 8 Natural Gas Conversion Kit 9 Protective Mesh Screen 10 Thermocouple 11 Electronic Igniter 12 Spark Electrode 13 Pebble Glass Kit Size 3 4 1 2...

Page 8: ...e to expand and cause a pop and launch outside of the fire pit which could cause injury or property damage Allow lava granules to completely dry after getting wet rained on or hosed off before lightin...

Page 9: ...ME AFTER USE YOU MUST MAINTAIN THE LAYOUT AS SHOWN TO ENSURE PROPER OPERATION OF YOUR FIRE PIT IF YOU NEED TO REPOSITION ANY MATERIAL TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW M...

Page 10: ...ferent Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correctl...

Page 11: ...ions Fire Pit Component Parts O W Lee extends a two 2 year limited warranty on all burner components under normal use and proper maintenance OW Lee will at factory option repair or replace any outdoor...

Page 12: ...tank valve is closed 2 Wait a minimum of 5 minutes for the gas to clear out OPERATING INSTRUCTIONS We recommend that before you install your Fire Pit you familiarize yourself with the control valve l...

Page 13: ...for various uses Propane itself is not a listed Proposition 65 chemical The combustion of propane in appliances such as stoves or heating systems and vehicles using propane creates harmful chemicals...

Page 14: ...nd replace it with the proper sized one for your gas requirement Propane requires the smaller orifice 4 If you are converting from propane LP gas to natural gas install the air shutter sleeve so that...

Page 15: ...n espace clos tel qu une caravane une tente une voiture ou la maison 4 Apr s avoir quitt les lieux appelez votre fournisseur de gaz ou le service d incendie DANGER Cet appareil gaz est con u comme un...

Page 16: ...AU MOINS 60 PO DU CENTRE DU BR LEUR TOUT MURS PLAFONDS OU MAT RIAUX COMBUSTIBLES LORSQUE VOUS TEIGNEZ L APPAREIL VEILLEZ COMMANDER LA VANNE DE CONTR LE DU PUITS D INCENDIE LA POSITION TOTALE DE L ALLU...

Page 17: ...rie du gaz doit tre dimensionn de sorte fournir la pression minimale d admission au d bit maximum BTU hr Une perte excessive de pression se produira si le tuyau est trop petit ou trop long G Casual Fi...

Page 18: ...nstallation et les r parations doivent tre effectu es par un technicien qualifi L appareil doit tre inspect avant utilisation et au moins une fois par an par un technicien qualifi Un nettoyage plus fr...

Page 19: ...e gaz GPL doit reposer sur la base inf rieure de la bouteille con ue pour permettre un retrait appropri de la vapeur 1 2 La ou les bouteilles de gaz LP utiliser doivent tre construites et marqu es con...

Page 20: ...z vous que la date de requalification des bouteilles est v rifi e Assurez vous que l vent du r gulateur ne pointe pas vers le haut Ne pas utiliser stocker ou transporter la bouteille dans un endroit o...

Page 21: ...arche arr t n 4 Bras De Contr le Soupape n 5 Ligne Flex 22 Chuchotement Silencieux n 6 Connecteur de bouteille de propane n 7 Orifice de propane n 8 Kit de conversion de gaz propane en gaz naturel n 9...

Page 22: ...tera chaud pendant un certain temps apr s utilisation VOUS DEVEZ MAINTENIR LA DISPOSITION COMME INDIQU E POUR ASSURER LE BON FONCTIONNEMENT DE VOTRE PUITS SI VOUS DEVEZ REPOSER TOUT MAT RIAU POUR MAIN...

Page 23: ...provoquer une expansion des gaz pi g s ou de l humidit et provoquer un clatement et un lancement pourrait causer des blessures ou des dommages mat riels Laissez les granules de lave s cher compl temen...

Page 24: ...ans le venturi et orifices des trous pour d gager le passage libre des toiles d araign es ou d autres d bris Assurez vous de tout remettre correctement lorsque vous avez termin pour le fonctionnement...

Page 25: ...ant Parties Pit Fire O W Lee offre une garantie limit e de deux 2 ans sur tous les composants du br leur en utilisation normale et appropri e entretien OW Lee sera l usine de r parer ou de remplacer t...

Page 26: ...ontr le du foyer ainsi que la vanne du r servoir de propane sont ferm es 2 Attendez au moins 5 minutes que le gaz se vide MODE D EMPLOI Nous vous recommandons de vous familiariser avec le sch ma de la...

Page 27: ...ue r pertori de la Proposition 65 La combustion de propane dans des appareils tels que des po les ou des syst mes de chauffage et des v hicules utilisant du propane cr e des produits chimiques nocifs...

Page 28: ...ce que les orifices d admission d air soient ferm s Figure 2 Pour le gaz propane retirez l obturateur d air de fa on ce que les orifices d admission d air soient ouverts Figure 1 Une fois que l unit e...