![Overkill Solar 120A 4s 12V BMS Instruction Manual Download Page 37](http://html1.mh-extra.com/html/overkill-solar/120a-4s-12v-bms/120a-4s-12v-bms_instruction-manual_1662874037.webp)
20% capacity voltage (per cell)
3100
mV
Protection parameters:
Parameter
Trigger Value
Release Value
Delay
(seconds)
Cell over voltage
3650 mV
3500 mV
2
Cell under voltage
2500 mV
3000 mV
2
Battery over voltage
14600 mV
14000 mV
2
Battery under voltage
10000 mV
12000 mV
2
Charge over current
130000 mA
32s
10
Discharge over current
130000 mA
32s
10
Charge over temp
65
℃
55
℃
2
Charge under temp
-1
℃
5
℃
2
Discharge over temp
75
℃
70
℃
2
Discharge under temp
-10
℃
0
℃
2