Installation
“Regumaq X-25”
24
138112581-V01.10.2019
Illust. 14: Use of the wall bracket as a drilling jig
6. Drill the corresponding holes (ø 8 mm) and insert
the dowels.
7. Screw the wall bracket into place with two
10x60 mm screws and washers (supplied).
8. Mount the product assembly on the wall bracket.
Ensure that the bracket audibly locks into
place. Ensure the station is seated securely on
the bracket.
9. Insert the washer into the designated contour in the
lower shell.
22
Illust. 15: Position of the washer
(22)
Position of the washer
10. Fix the lower shell with the screw with hexagon
socket (M5 x 20). Tighten the screw until metallic
stop.
This completes the wall attachment of the fresh wa-
ter station. The next step involves the pipework.