en
35
7.2
Solar
In the
Status / Solar
menu, the status of the solar
system, the solar loading and the selected optional
functions are indicated.
7.3
Arrangement
In the
Status / Arrangement
menu, the status of the
selected optional functions is indicated.
7.4
Heating
In the
Status / Heating
menu, the status of the de-
mands and heating circuits activated as well as of the
selected optional functions is indicated.
7.5
Messages
In the
Status / Messages
menu, error and warning mes-
sages which have not been acknowledged are indicated.
During normal operation, the message
Everything
OK
is indicated.
A line break or short circuit in a sensor line is indi-
cated as
! Sensor fault
. A precise error code can be
found in the Status / Meas.- / Balance values menu.
If the optional function Flow rate monitoring is acti-
vated and has detected an error, the message
!Flow r.
monit.
is indicated.
All messages will additionally be displayed in the cor-
responding menus. In order to acknowledge an error
message , the corresponding menu has to be entered.
If, for example, the message
!Flow r. monit.
appears,
it will also be displayed in the Solar / Optional func-
tions / Flow rate monitoring. In that menu, the mes-
sage can be acknowledged.
7.6
Service
In the
Status / Service
menu, each sensor and relay
is indicated with the component or function it has
been allocated to. For free sensors and relays,
Free
is indicated.
8
Solar
In this menu, all adjustments for the solar part of the
arrangement can be made. The Solar menu consists of
the following submenus:
• Basic setting
• Optional functions
• Expert
8.1
Basic solar settings
In this menu, all basic settings for the solar part of the
arrangement can be adjusted.
In this menu, the hydraulic system, which is the basis
for the arrangement, can be adjusted. The setting is
divided into systems and variants.
Both system and variant have usually been adjusted
during commissioning. If the setting is changed later
on, all adjustments for the solar part of the arrange-
ment are set back to their factory settings.
Note:
If the change causes the solar system to re-
quire a relay that has been allocated to an ar-
rangement or heating function before, all ad-
justments made in the non-solar function will
be set back to their factory settings as well.