Removal
“Aktor MH CON B (ENOCEAN)”
10/12
5. Removal “Aktor MH CON B (ENOCEAN)”
Set the actuator to its installation position before removal.
Wear safety gloves and goggles if required.
Risk of scalding due to an uncontrolled escape of hot
water!
If the drive shaft is not retracted, the valve may inadvertently be
unscrewed from the radiator during removal which may lead to an
uncontrolled escape of hot water from the radiator.
ATTENTION
5.1 Re-commissioning after removal (in “teached in” state)
Please observe that the actuator is still adapted to the Smart Home System
after removal from the radiator valve. As an automatic adjustment run is only
triggered by the actuator during the initial “teach in” process (see step 5, page
8), a manual adjustment run has to be triggered when mounting the actuator
onto another radiator valve.
To do so, keep the “teach in”/adjustment button (A) pressed for more than
3 seconds. Now the drive shaft moves towards the radiator valve and the
actuator is ready for operation again. Both LEDs will flash green three times.
IMPORTANT NOTE
Before removal, the actuator has to be set to its
installation position. To do so, keep the “teach
in/adjustment” button (A) pressed for more than
3 seconds so that drive shaft of the actuator
retracts.
After having reached the installation position, both LEDs will flash green
quickly five times.
A