background image

OVM_FT-0113

9

Check Fans Is Lit (Red Light)

Check Fans Is Lit

(Red Light)

Check that air

filters are clean

and not obstructed

Obstruction exists

Not Obstructed

Clean/replace

filter(s) or

remove

obstruction

With air filters removed,

check that each fan is 

drawing air

All 4 fans are OK

One fan is not OK

2 fans on the same

side are not OK

None of the four fans 

are OK

Using the visual view

screen, check it the relay

board temperature is

below 120°F

Check that AC power

is at the fan

Check that AC power

is at the fans

Check for AC present

on relay board

connector J1

Relay board

temperature is

≥ 120°F

Check fan

light is on.

This is

normal

Repair/

replace

wiring as

necessary

Replace

the 2

non-working

fans

Replace

the fan

wiring

Plug in fans

Replace

relay board

Check relay

board to fan

wiring and repair

or replace

as needed

Replace the

non-working

fan

Replace

relay board

Replace the

cutoff switch

that has

continuity

Relay board

temperature is

below 120°F

Check continuity

of both thermal

cutoff switches

AC not OK on

relay board

connector J1

AC OK on

relay board

connector J1

Check wiring

from 10 amp

fuses, through

terminal blocks

TB3 & TB4 to

relay board

connector J1

No AC power

at the fans

AC power is

at the fans

Check that fans

are plugged in

AC power is

present at the

non-working fan

AC power is not

present at the

non-working fan

Fans are

plugged in

Fans are not 

plugged in

Check for AC

present on relay

board connectors

J18–J21

AC OK on

relay board

connectors

AC not OK on

relay board

connectors

Summary of Contents for Matchbox M1313

Page 1: ... 2013 Ovention Inc Diagnostic Fault Tree P N 07 04 633 00 Matchbox Oven Models M1718 M1313 ...

Page 2: ... tree Intermediate Event An event in the hierarchical fault tree that logically leads to the top level event but is at a lower level than the top event Basic Initiating Event An event in the hierarchical fault tree that is at the end of a branch in the tree It is the lowest level in a particular branch that is considered during the fault tree analysis The fault tree may have many branches each wit...

Page 3: ... continuity OK Heater continuity not OK Replace Relay Board Replace Heater Replace Heater Check thermocouples Thermocouple readings OK Thermocouple readings not OK Replace Relay Board Replace Relay Board Replace Relay Board Check thermocouple connections Thermocouple connections OK Thermocouple connections not OK Reseat thermocouple connections Verify UI board to relay board communications Replace...

Page 4: ...the RJ45 cable outside of door for 24 VDC Check 24 VDC on UI board inside of door 24 VDC found OK 24 VDC not found on UI board 24 VDC found on UI board No 24 VDC found Check input voltage wiring 10 A fuses Correct input voltage wiring or 10 A fuses as appropriate PTC 2 is good light is off PTC 2 is not good light is on Check that 24 VDC supply is good Check RJ45 cable for shorts or signs of pinchi...

Page 5: ...ed Unresponsive screens problem resolved Replace screen Screen is cracked Screen is not cracked Remove oven door Check that touchscreen cable is properly seated in connector and not damaged Unresponsive screens problem persists Unresponsive screens problem persists Replace UI board Touchscreen cable is not properly seated in connector Touchscreen cable is properly seated in connector and is not da...

Page 6: ...tire range in both directions checking for areas of binding or interference No binding or interference observed Binding or interference is observed Check that stepper motor connections are OK Assure food doesn t extend over cooking tray and isn t too high for door opening Food size and positioning is OK If food size or positioning is not OK correct this Check linear bushing and rolling bushing Lin...

Page 7: ...s uncooked on top side or on bottom side or on both sides in this diagnostic flow Thermocouple readings OK Thermocouple connections OK Verify UI board to relay board communications Thermocouple connections notOK Thermocouple readings not OK Check Thermocouple connections Replace relay board Replace relay board Replace relay board Replace RJ45 cable Reseat thermocouple connections UI board to relay...

Page 8: ...t of doors and cavity Slider is not at the end of travel Slider is at the end of travel Proceed to Slider Doesn t Complete Travel Or Doesn t Move At All diagnostic flow Check the alignment of the magnet on the slider to the proximity switch closest to it Proximity switch and magnet are aligned Proximity switch and magnet are not aligned Align proximity switch and magnet Disconnect the proximity sw...

Page 9: ...ring as necessary Replace the 2 non working fans Replace the fan wiring Plug in fans Replace relay board Check relay board to fan wiring and repair or replace as needed Replace the non working fan Replace relay board Replace the cutoff switch that has continuity Relay board temperature is below 120 F Check continuity of both thermal cutoff switches AC not OK on relay board connector J1 AC OK on re...

Page 10: ...the other blower motor No Neither blower motor has excessive vibration Yes One blower motor has excessive vibration Replace the faulty blower motor assembly Check for obstructions in the air paths and correct or remove obstruction Allow oven to cool and go to maintenance mode To isolate the source of the whistling turn on top blower to 100 and bottom blower to 0 listening for whistling sounds from...

Page 11: ...itch for 10 seconds then turn back on Replace UI board Problem resolved Problem persists Oven Clock Doesn t Keep Correct Time Does oven not keep correct time only when oven power is cycled off and on Replace UI board Replace coin battery on UI board Oven doesn t keep correct time even if power is not cycled off and on Oven doesn t keep correct time when power is cycled off and on ...

Page 12: ...rol panel that speaker volume is not turned off Replace speaker Replace relay board Problem resolved Still no audible beep at end of cook cycle Check on power up that a rev for the relay board is displayed Audible beep now occurs at end of cook cycle If rev is not 0 00 If rev is 0 00 refer to other symptoms as appropriate ...

Page 13: ...ty switch and magnet are not aligned Proximity switch and magnet are aligned Disconnect the proximity switch via the inline connector near the switch Check for continuity at the switch when the slider magnet is next to switch Continuity OK Check for switch continuity measured at J4 J5 of relay board Replace switch and slider magnet No continuity Continuity OK Replace wire Replace relay board No co...

Page 14: ...etpoint temperature Oven is not cooling to within 50 F of setpoint temperature Oven is slow to warm to within 50 F of setpoint temperature Check that top and bottom heaters are not reversed Check heater current Allow oven to cool Allow oven to warm Turn off main disconnect switch for10 seconds then turn back on Turn off main disconnect switch for 10 seconds then turn back on Oven is cooling to wit...

Page 15: ...elay board Check wiring on relay board J11 for bottom blower or J24 for the top blower Check for less than 9 VDC on relay board pins 1 2 of J11 J24 Check whether the yellow light on the VFD is blinking or lit continuously Replace relay board Replace blower motor assembly Replace blower motor assembly Fix the connections Repair replace connections or wiring as appropriate Yellow light is blinking Y...

Page 16: ...06 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERSEY Jay Hill Repair Fairfield 973 575 9145 Service Plus Flanders 973 691 6300 NEW YORK Acme American Repairs Inc Brooklyn 718 456 6544 Alpro Service Co Brooklyn 718 386 2515 Appliance Installation Buffalo 716 884 7425 Duffy s Equipment Services Inc Buffalo 800 836 1014 3Wire Northern Plattsburgh 800 634 5005 Duffy s Equipment Services I...

Reviews: