background image

9

Version 1.0

www.ovationlight.com

CH5 is used to select the target ID address.

DMX value

Function

DMX value

Function

DMX

 

value

Function

000-009

ID1-ID66

212

ID23

235

ID46

010-019

ID1

213

ID24

236

ID47

020-029

ID2

214

ID25

237

ID48

030-039

ID3

215

ID26

238

ID49

040-049

ID4

216

ID27

239

ID50

050-059

ID5

217

ID28

240

ID51

060-069

ID6

218

ID29

241

ID52

070-079

ID7

219

ID30

242

ID53

080-089

ID8

220

ID31

243

ID54

090-099

ID9

221

ID32

244

ID55

100-109

ID10

222

ID33

245

ID56

110-119

ID11

223

ID34

246

ID57

120-129

ID12

224

ID35

247

ID58

130-139

ID13

225

ID36

248

ID59

140-149

ID14

226

ID37

249

ID60

150-159

ID15

227

ID38

250

ID61

160-169

ID16

228

ID39

251

ID62

170-179

ID17

229

ID40

252

ID63

180-189

ID18

230

ID41

253

ID64

190-199

ID19

231

ID42

254

ID65

200-209

ID20

232

ID43

255

ID66

210

ID21

233

ID44

211

ID22

234

ID45

Fixture Cleaning

Due to fog residue, smoke, and dust cleaning the internal and external optical lenses and mirror should 

be carried out periodically to optimize light output. Cleaning frequency depends on the environment in 

which the fixture operates (I.e. smoke, fog residue, dust, dew). In heavy club use we recommend clean

-

ing on a monthly basis. Periodic cleaning will ensure longevity, and crisp output.

To clean the fixture:

1. 

Disconnect the fixture from power and allow it to cool for at least 10 minutes.

2. 

Vacuum or gently blow away dust and loose particles from the outside of the fixture with low-pressure 

compressed air.

3.  Clean the surfaces by wiping gently with a soft, clean lint-free cloth moistened with a weak detergent 

solution. Do not rub glass surfaces hard: lift particles off with a soft repeated press. Dry with a soft, 
clean, lint-free cloth or low-pressure compressed air. Remove stuck particles with an unscented tis

-

sue or cotton swab moistened with glass cleaner or distilled water.

4. 

Check that the fixture is dry before reapplying power.

Fuse Replacement

This fuse is located in a fuseholder next to the MAINS OUT socket on the connections panel.
To replace a fuse:

1. 

Disconnect the fixture from power and allow it to cool for at least 10 minutes.

2. 

Unscrew the cap of the fuseholder and remove the fuse. Replace with a fuse of the same size and 

rating only.

3. 

Reinstall the fuseholder cap before reapplying power.

Troubleshooting

Listed below are a few common problems that you may encounter, with solutions.

Summary of Contents for Pioneer 100 ZOOM WW/CW

Page 1: ...USER MANUAL PIONEER 100 ZOOM WW CW 100W LED fresnel with zoom ...

Page 2: ...he fixture on a truss 5 Securing with a safety cable 5 DMX 512 connection connection between fixtures 5 Power connection 6 Operation 6 Control Menu Map 6 Addressing 7 Universal DMX Control 7 RDM control 7 DMX Protocol 7 ID address selection 8 Fixture Cleaning 9 Fuse Replacement 9 Troubleshooting 10 The fixture does not work no light 10 Technical specifications 10 Table of contents ...

Page 3: ...ts of the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual consider this manual to be part of the total product keep this manual for the entire service life of t...

Page 4: ... this user manual using a securely anchored safety cable that will hold the fixture if the primary fastening method fails Fastening the fixture to a flat surface The fixture can be fastened to a hard fixed flat surface that is oriented at any angle Ensure that the sur face and all fasteners used can support at least 10 times the weight of all fixtures and equipment to be installed on it Fasten the...

Page 5: ...ough the eyebolt in the back of the fixture and around a secure anchoring point Do not loop the safety cable around the fixture s mounting bracket only as this will leave the fixture un secured if it separates from the bracket DMX 512 connection connection between fixtures Occupation of the XLR connection 1 Group 2 Signal 3 Signal DMX OUT 1 Group 2 Signal 3 Signal DMX IN If you are using controlle...

Page 6: ...nnection cables as below Cable color Connection International Brown Live L Blue Neutral N Yellow green Earth Ground Operation The Pioneer 100 zoom can operate different modes In each mode you can run the fixture as a stand alone fixture or in a master slave confiugration This next section will detail the differences in the operat ing modes Control Menu Map MENU SUB MENU OPERATION Addr d001 d512 RD...

Page 7: ... for example the ad dress in the 2 channel mode to channel 3 the device will use the channel 3 to 4 for control Universal DMX Control This function allows you to use a universal DMX 512 controller to control the dimmer and strobe A DMX controller allows you to create unique programs tailored to your individual needs RDM control The Pioneer 100 zoom can communicate using RDM Remote Device Managemen...

Page 8: ...r speed 3 206 255 Dimmer speed 4 slowest speed 5 Channels Mode Function Function Control CH1 Dimmer 000 255 0 100 dimmer CH2 Strobe 000 255 strobe with speed increasing CH3 Zoom 000 255 zoom function CH4 Dimmer mode 000 005 Menu setting 006 055 Dimmer speed 0 no delay 056 105 Dimmer speed 1 106 155 Dimmer speed 2 156 205 Dimmer speed 3 206 255 Dimmer speed 4 slowest speed CH5 ID address setting 00...

Page 9: ...tes I e smoke fog residue dust dew In heavy club use we recommend clean ing on a monthly basis Periodic cleaning will ensure longevity and crisp output To clean the fixture 1 Disconnect the fixture from power and allow it to cool for at least 10 minutes 2 Vacuum or gently blow away dust and loose particles from the outside of the fixture with low pressure compressed air 3 Clean the surfaces by wip...

Page 10: ...K optional Color Rendition CRI 97 R9 90 TLCI up to 98 Zoom scale 25 65 motorized Power connection PowerCON in out Maximum power linking 8 units Signal connection 3 pin XLR in out 5 pin optional DMX channels 2 3 4 5 Control mode RDM DMX Master slave Housing Colour black Aluminum Size barn door excluded 331 x 210 x 345 7mm 13 x 8 3 x 13 6in Package carton 448 x 338 x 400mm 17 6 x 13 3 x 15 7in N W 6...

Reviews: