Addressing

All fixtures should be given a DMX starting address when using a DMX signal, so that the correct fixture

responds to the correct control signals. This digital starting address is the channel number from which 

the fixture starts to listen to the digital control information sent out from the DMX controller. The alloca

-

tion of this starting address is achieved by setting the correct number on the display located on the base 
of the device.

You can set the same starting address for all fixtures or a group of fixtures, or make different address for
each fixture individually.

If you set the same address, all the units will start to listen to the same control signal from the same 

channel number. In other words, changing the settings of one channel will affect all the fixtures simulta

-

neously.

If you set a different address, each unit will start to listen to the channel number you have set, based on 
the quantity of control channels of the unit. That means changing the settings of one channel will affect 

only the selected fixture.

In the case of the Pioneer 100 zoom, which is 2/3/4/5 channels fixture. If you set, for example, the ad

-

dress in the 2 channel mode to channel 3, the device will use the channel 3 to 4 for control.

Universal DMX Control

This function allows you to use a universal DMX-512 controller to control the dimmer and strobe. A DMX 

controller allows you to create unique programs tailored to your individual needs.

RDM control

The Pioneer 100 zoom can communicate using RDM (Remote Device Management) in accordance with 
ESTA’s American National Standard E1.20-2006: Entertainment Technology RDM Remote Device Man

-

agement Over DMX512 Networks.

RDM is a bi-directional communications protocol for use in DMX512 control systems, it is the open stan

-

dard for DMX512 device configuration and status monitoring.

The RDM protocol allows data packets to be inserted into a DMX512 data stream without affecting ex

-

isting non-RDM equipment. It allows a console or dedicated RDM controller to send commands to and 
receive messages from specific fixtures.

With RDM function, you can set the DMX address of your fixtures remotely. This is especially useful 

when the device is installed in a remote area.

Each Pioneer 100 zoom has a factory set RDM UID (unique identification number).

DMX Protocol

2 Channels Mode

Function

Function Control

CH1

Dimmer

000-255: 0-100% dimmer

CH2

Zoom

000-255: zoom function

3 Channels Mode

Function

Function Control

CH1

Dimmer

000-255: 0-100% dimmer

Summary of Contents for Pioneer 100 ZOOM WW/CW

Page 1: ...USER MANUAL PIONEER 100 ZOOM WW CW 100W LED fresnel with zoom ...

Page 2: ...he fixture on a truss 5 Securing with a safety cable 5 DMX 512 connection connection between fixtures 5 Power connection 6 Operation 6 Control Menu Map 6 Addressing 7 Universal DMX Control 7 RDM control 7 DMX Protocol 7 ID address selection 8 Fixture Cleaning 9 Fuse Replacement 9 Troubleshooting 10 The fixture does not work no light 10 Technical specifications 10 Table of contents ...

Page 3: ...ts of the housing can become hot during operation After use wait for a cool down period of at least 10 minutes before handling or transporting the device Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual consider this manual to be part of the total product keep this manual for the entire service life of t...

Page 4: ... this user manual using a securely anchored safety cable that will hold the fixture if the primary fastening method fails Fastening the fixture to a flat surface The fixture can be fastened to a hard fixed flat surface that is oriented at any angle Ensure that the sur face and all fasteners used can support at least 10 times the weight of all fixtures and equipment to be installed on it Fasten the...

Page 5: ...ough the eyebolt in the back of the fixture and around a secure anchoring point Do not loop the safety cable around the fixture s mounting bracket only as this will leave the fixture un secured if it separates from the bracket DMX 512 connection connection between fixtures Occupation of the XLR connection 1 Group 2 Signal 3 Signal DMX OUT 1 Group 2 Signal 3 Signal DMX IN If you are using controlle...

Page 6: ...nnection cables as below Cable color Connection International Brown Live L Blue Neutral N Yellow green Earth Ground Operation The Pioneer 100 zoom can operate different modes In each mode you can run the fixture as a stand alone fixture or in a master slave confiugration This next section will detail the differences in the operat ing modes Control Menu Map MENU SUB MENU OPERATION Addr d001 d512 RD...

Page 7: ... for example the ad dress in the 2 channel mode to channel 3 the device will use the channel 3 to 4 for control Universal DMX Control This function allows you to use a universal DMX 512 controller to control the dimmer and strobe A DMX controller allows you to create unique programs tailored to your individual needs RDM control The Pioneer 100 zoom can communicate using RDM Remote Device Managemen...

Page 8: ...r speed 3 206 255 Dimmer speed 4 slowest speed 5 Channels Mode Function Function Control CH1 Dimmer 000 255 0 100 dimmer CH2 Strobe 000 255 strobe with speed increasing CH3 Zoom 000 255 zoom function CH4 Dimmer mode 000 005 Menu setting 006 055 Dimmer speed 0 no delay 056 105 Dimmer speed 1 106 155 Dimmer speed 2 156 205 Dimmer speed 3 206 255 Dimmer speed 4 slowest speed CH5 ID address setting 00...

Page 9: ...tes I e smoke fog residue dust dew In heavy club use we recommend clean ing on a monthly basis Periodic cleaning will ensure longevity and crisp output To clean the fixture 1 Disconnect the fixture from power and allow it to cool for at least 10 minutes 2 Vacuum or gently blow away dust and loose particles from the outside of the fixture with low pressure compressed air 3 Clean the surfaces by wip...

Page 10: ...K optional Color Rendition CRI 97 R9 90 TLCI up to 98 Zoom scale 25 65 motorized Power connection PowerCON in out Maximum power linking 8 units Signal connection 3 pin XLR in out 5 pin optional DMX channels 2 3 4 5 Control mode RDM DMX Master slave Housing Colour black Aluminum Size barn door excluded 331 x 210 x 345 7mm 13 x 8 3 x 13 6in Package carton 448 x 338 x 400mm 17 6 x 13 3 x 15 7in N W 6...