16.2 Register General Specifications
Item
Size 50
※
, 52, 53
※
55, 56 57
Local Total count (8-digit)
Display Resettable
C mode
(LCD) total(7-digit)
Mode Instantaneous b1 mode
1 L/h (standard)
1 L/h (standard)
Select flowrate (4-digit) b2 mode
0.01 L/min. (standard)
0.01 L/min. (standard)
−
None
Local display only
Analog
4 - 20mA DC See the acceptable load resistance range on page 14.
Type
Factored or unfactored: 0/1 = 4/20mA DC
Pulse
Pulse width
Factored: 1 ms (standard), 50 ms Unfactored: 2 ms
Voltage pulse unit Same as the indicated unit
Type
Factored or unfactored: NPN transistor output (Max. voltage impression 30V DC,
Allowable current 50mA, Transistor "ON" voltage: 1.5V DC max.)
Pulse
Pulse width
Factored: 1 ms (standard), 50 ms Unfactored: 2 ms
Voltage pulse unit Same as the indicated unit
Type
Factored or unfactored: 0/1 = 1V DC max. / 7V DC min.
Pulse
Pulse width
Factored: 1 ms (standard), 50 ms Unfactored: 2 ms
Voltage pulse unit Same as the indicated unit
Output not provided
Built-in dedicated lithium battery. Good for 8 yrs. approx. (Depends on operating conditions.)
External power source 12 - 45V DC (analog, current pulse)
12 - 24V DC (open collector pulse, voltage pulse)
Output provided
12 - 45V DC (analog, current pulse combined)
Current drain: 30mA DC max. See the acceptable load resistance range on page 14. (Note 1)
Signal Transmission Cable
Shielded cable 1.25mm
2
in conductor area Finished O.D. 8.5 - 12 mm
(Note 2)
Transmission Length
One kilometer
2-wire system Analog or current pulse
Transmission Lines 3-wire system Open collector pulse or voltage pulse
4-wire system current pulse
Ambient Temperature
- 10 to + 60
°
C
Select either one of the following:
Construction
①
Non-explosionproof type
②
TIIS
:
Exd
Ⅱ
B T4 /Exia
Ⅱ
B T4, Exia
Ⅱ
B T3
③
NEPSI
:
Exd
Ⅱ
B T4
④
KOSHA
:Ⅱ
2G Exd
Ⅱ
B T4
⑤
FM
:
Class I, Division I / Group C, D T4 AEx / Exd
Ⅱ
B T4
⑥
KCs
:
Exd
Ⅱ
B T4
⑦
ITRI
:
Exd
Ⅱ
B T4 Gb
⑧
EAC
:
1 Exd
Ⅱ
B T4
Enclosure Protection Rating
IP66 (dusttight / watertight) IEC / EN60529, JIS C 0920
Housing Material
Aluminum die casting
Finish
Munsell 2.5PB 5/8, (baked melamine)
NOTES:
1. When powered by the battery pack, the register provides local readout only with no remote output signal.
2. For wiring of explosionproof type (output available models), do not fail to use the ancillary pressure-
resistant packing.
Also, in case of TIIS explosionproof type used under the ambient temperature of 45
℃
or higher, use a
cable resistant to the temperature of 75
℃
or higher.
3. If pulse width in excess of 1ms is desired with minimum factored pulse unit, the max. flowrate can
possibly be restricted; consult the factory.
4. With meter size marked
※
, if minimum factored pulse unit is selected, pulse width other than 1ms
is unacceptable.
Construction
O
ut
pu
t
Vo
lta
ge
O
pe
n
co
lle
ct
or
Cu
rre
nt
Cu
rre
nt
0.01L(standard)
0.1L, 1L
0.1L(standard)
1L, 0.01
㎥
1L(standard)
0.01
㎥
, 0.1
㎥
(Note 3,4)
(Note 3,4)
(Note 3,4)