7
6
INSTRUCTION
INSTRUCTION
5.1 Scope of functions
• Power supply with priority circuit for connecting to the AC mains
• Three-level battery monitor to protect the vehicle battery
• Display with temperature gauge in ºC and ºF
• Switches off and automatically at low battery voltage
• Temperature setting: With two buttons in steps of 1ºC(2ºF)
• Foldable carrying handles
• Emergency switch (where fitted)
• Removable wire basket
5.2 Operating and display elements
Latch for lid, fig.2
Operating panel, fig3
INSTRUCTION
Connection sockets, fig4
Emergency switch (when fitted), fig5
Item
Description
Explanation
1
ON
OFF
Switches the cooler on or off when the button is pressed for between
one and two seconds
2
POWER
Status indication
LED lights up green: Compressor is on
LED lights up orange: Compressor is off
3
ERROR
Number of flashes
Error Type
LED flashes red
5
Thermal cut-out of controller
4
Minimum motor speed error
3
Motor start error
2
Fan over-current cut-out
1
Battery protection cut-out
4
SET
Selects the input mode
-Temperature setting
-Celsius or Fahrenheit display
-Set battery monitor
5
POWER
Display, shows the information
6
Press once to increase the value
7
Press once to decrease the value
Item
Description
1
Connection socket DC voltage supply