background image

 

 

ISSUED BY: 

 

 

REVIEWED BY: 

 

 

REVISION 2.0 

 

 
 

CHEST FREEZER 
Model : TSD-27CF 

 
 
 
 
    

 

        

TSD-27CF

 

 
 
 
 
 
 
 
 
Specification: Subject to change without notice. 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

SPECIFICATION TSD-27CF 

Classification 

Direct Cool, Manual Defrost, Tropical 

Power Source 

115VAC, 60 Hz. 

Volume 

138 Liters (4.9 cu.ft) 

Rated Current 

2.0 Amp.   

Rated Power Input 

135 Watts 

Power Consumption 

1.30 kW

·

h/24h 

High side  /Low side 

pressure 

155psig/-2.22psig 

Refrigerant HFC-134a 

(Tetrafluoroethane) CF

3

CH

2

F 115gm 

Overall Dimension 

695(W) x595(D) x 910(H) mm  

 

 

Net Weight/Gross Weight  45 Kg./50 Kg. 

S

ERVICE

 

M

ANUAL

 

Summary of Contents for TSD-27CF

Page 1: ...rect Cool Manual Defrost Tropical Power Source 115VAC 60 Hz Volume 138 Liters 4 9 cu ft Rated Current 2 0 Amp Rated Power Input 135 Watts Power Consumption 1 30 kW h 24h High side Low side pressure 15...

Page 2: ...or Lamp None Fan Motor None Compressor KONOR GQY50AD 135 Watts Compressor Oil 290 ml POE Polyol Ester Synthetic PTC Starter 8115PTH7M4R7MC1 3 8 5 6 Max current 18A 180V Overload Protector 11650X011 si...

Page 3: ...CHEST FROZEN SHOWCASE TSD 27CF ELEC CIRCUIT TSD 27CF COOLING SYSTEM TSD 27CF...

Page 4: ...ermostat 1 208 Thermostat panel 1 209 Red indicator light 1 210 Green indicator light 1 211 Thermostat knob 1 212 Thermostat panelcover 213 Castor 2 4 214 Base support 1 215 Screw ST4 2x16 C H 4 216 C...

Page 5: ...Compressor electric box clip 1 308 PTC starter 1 309 Compressor process tube 1 401 Screw M4x22 2 402 Connector box cover 1 403 Connector box support 1 404 Power cord retainer base 1 405 Power cord 1...

Page 6: ...CHEST FROZEN SHOWCASE TSD 27CF Exploded View of TSD 27CF...

Page 7: ...C Min action current 3 36A 70 Overload Protector Model TSD 27CF Abnormal Open TROUBLE SHOOTING Thermostat Repair Procedure 1 Set Thermo Knob to OFF position pull straightened feeler bulb 2 Remove Ther...

Page 8: ...electrical circuit Worn out or defective A C cord Replace Check lamp Open Replace No Light Check lamps socket Corroded Replace Low Cooling Check for thermo setting Setting too low Set thermostat high...

Page 9: ...rect Cool Manual Defrost Tropical Power Source 115VAC 60 Hz Volume 208 Liters 7 3 cu ft Rated Current 3 0 Amp Rated Power Input 200 Watts Power Consumption 1 80 kW h 24h High side Low side pressure 15...

Page 10: ...or Lamp None Fan Motor None Compressor KONOR GQY70AD 165 Watts Compressor Oil 290 ml POE Polyol Ester Synthetic PTC Starter 8115PTH7M4R7MC1 3 8 5 6 Max current 18A 180V Overload Protector 11650X011 si...

Page 11: ...CHEST FROZEN SHOWCASE TSD 35CF ELEC CIRCUIT TSD 35CF COOLING SYSTEM TSD 35CF...

Page 12: ...indicator light 1 213 Thermostat knob 1 215 Dryer filter 1 216 Dryer filter support 1 217 Cappilary tube 1 218 suction tube 1 219 Base support 1 220 Screw ST4 2x16 C H 4 221 Screw 4 2x16 C H 2 222 Ca...

Page 13: ...tion gasket 4 315 Nut M4 2 316 spring 2 317 Fan motor 1 318 Fan cool condenser 1 401 Screw M4x22 2 402 Connector box cover 1 403 Connector box support 1 404 Power cord retainer base 1 405 Power cord 1...

Page 14: ...CHEST FROZEN SHOWCASE TSD 35CF Exploded View of TSD 35CF...

Page 15: ...TC Min action current 3 36A 70 Overload Protector Model TSD 35CF Abnormal Open TROUBLE SHOOTING Thermostat Repair Procedure 1 Set Thermo Knob to OFF position pull straightened feeler bulb 2 Remove The...

Page 16: ...electrical circuit Worn out or defective A C cord Replace Check lamp Open Replace No Light Check lamps socket Corroded Replace Low Cooling Check for thermo setting Setting too low Set thermostat high...

Page 17: ...t Tropical Power Source 115VAC 60 Hz Volume 298 Liters 10 5 cu ft 318 Liters 11 2 cu ft Rated Current 2 5 Amp Rated Power Input 270 Watts Power Consumption 3 2 kW h 24h 3 5 kW h 24h High side Low side...

Page 18: ...3CH2F Refrigerant Charge gm 215 gm Door Lamp None Fan Motor ZCF 200 100V 125V 60Hz Compressor DONPER EU1121BZ 160 Watts Compressor Oil 290 ml POE Polyol Ester Synthetic PTC Starter QP2 4 7C Overload P...

Page 19: ...CHEST FROZEN SHOWCASE TSD 47CF TSD 60CF ELEC CIRCUIT TSD 47CF TSD 60CF COOLING SYSTEM TSD 47CF TSD 60CF...

Page 20: ...older B 1 208 Side cover holder C 1 209 thermostat 1 210 Thermostat panel 1 211 Red indicator light 1 212 Green indicator light 1 213 Thermostat knob 1 215 Dryer filter 1 216 Dryer filter support 1 21...

Page 21: ...e 1 310 Nut M6 4 311 Spring 4 312 Screw M5x10 2 313 anti vibration gasket cover 4 314 Compressor anti vibration gasket 4 315 Nut M4 2 316 spring 2 317 Fan motor ZCF 200 1 318 Fan cool condenser 1 401...

Page 22: ...CHEST FROZEN SHOWCASE TSD 47CF TSD 60CF Exploded View of TSD 47CF...

Page 23: ...CHEST FROZEN SHOWCASE TSD 47CF TSD 60CF Exploded View of TSD 60CF...

Page 24: ...verload current 27A UTC Min action current 3 36A 70 Overload Protector Model TSD 47CF TSD 60CF Abnormal Open Measure the resistance with a tester Ambient temperature Room temperature 25 c Model CBB60...

Page 25: ...5 Recharge refrigerant test run and seal system TROUBLE INSPECTION CAUSES REMEDY Check electric power supply voltage Open circuit breaker or fuse Fix or replace Open Fuse Replace No Power Check elect...

Page 26: ...CHEST FROZEN SHOWCASE TSD 47CF TSD 60CF oil choke with nitrogen to remove clogs 2 Repair or replace clogged section evacuate purge check leak and re charge refrigerant Test Run and seal system...