background image

En-2

  1-888-514-1663  |  

WWW.OUTLANDLIVING.COM

LP SAFETY:

a.   Do not store a spare LP-gas cylinder under or near this 

appliance. 

b.  Never fill the cylinder beyond 80 percent full. 
c.   If the information in “(a)” and “(b)” is not followed exactly, a 

fire causing death or serious injury may occur.

Do not use this appliance under overhead combustible surfaces.

MINIMUM CLEARANCES:

•  Bottom: Non-Combustible Surface
•  Top: 2 m / 80 in
•  Sides: 0.91 m / 36 in 
•   For Installation on (or over) non-combustible floors only

Input:  58,000 Btu/h (17 kW) and manifold pressure:  

11 in wc (2.74 kPa) 

Min. gas supply for input adj. 11 in wc (2.74 kPa)  
Max. gas supply: 
11 in wc (2.74 kPa) 
Injector Size* 2.32 mm
* Injector size marked clearly on the gas valve orifice.
Type of Gas: Propane (LP)

This appliance shall be used only outdoors in a well-ventilated 
space and shall not be used in a building, garage or any other 
enclosed area. 

The gas supply must be turned off at the LP-gas supply cylinder 
when this appliance is not in use.

Indoor storage of this appliance is permissible only if the cylinder 
is disconnected and removed from the appliance. 

Cylinders must be stored outdoors in a well-ventilated area out of 
the reach of children. 

Disconnected cylinders must have threaded valve plugs tightly 
installed and must not be stored in a building, garage or any other 
enclosed area. 

The gas pressure regulator provided with this appliance must be 
used and must be the same model as supplied with the unit. 

The cylinder supply system must be arranged for vapor 
withdrawal. 

Cylinders used with this unit must have a collar to protect the 
cylinder valve. 

An approved LP-Cylinder stabilizer, such as the stabilizer ring 
included, must be used when the appliance is in use.

Replacement parts and a list of such parts are available from FMI 
Brands Inc. through the contact information provided on the last 
page of this Manual.

 

 WARNING:

Please ensure that all adults and children which use or are 
near a unit in use are aware of the hazard of high-surface 
temperatures present on the unit during use and should use 
caution and stay away to avoid burns or clothing ignition. 

Carefully supervise young children in the area of this 
appliance. Clothing or other flammable materials should 
not be hung from the appliance or placed on or near the 
appliance. Any guard or other protective device removed for 
servicing the appliance must be replaced prior to operating 
the appliance. 

Installation and repair should be done by a qualified 
service person. The appliance should be inspected before 
use and at least annually by a qualified service person. 
More frequent cleaning may be required as necessary. It is 
imperative that control compartment, burners and circulating 
air passageways of the appliance be kept clean. 

 

 WARNING:

Improper installation, adjustment, alteration, service or 
maintenance can cause injury or property damage. Read 
the installation, operating and maintenance instructions 
thoroughly before installing or servicing this equipment.

 WARNING:

If the information in this manual is not followed exactly, 
a fire or explosion may result causing property damage, 
personal injury or loss of life.

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

Summary of Contents for FMPPC2A-895

Page 1: ...8 294 0988 Email info outlandliving com Hours of Operation 8 30AM 4 00PM Pacific Time Customer Service in English only 58 000 Btu h D 895 000 V0 Model number FMPPC2A 895 Registered trademark of FMI Br...

Page 2: ...r use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other applia...

Page 3: ...ylinders used with this unit must have a collar to protect the cylinder valve An approved LP Cylinder stabilizer such as the stabilizer ring included must be used when the appliance is in use Replacem...

Page 4: ...CONNECTION 1 Be sure the cylinder valve and appliance valves are off 2 Place full LP gas cylinder on tank stabilizer ring 3 Center the nipple in the cylinder valve and hold in place 4 Using the other...

Page 5: ...with either the National Fuel Gas Code ANSI Z223 1 NFPA 54 Natural Gas and Propane Installation Code CSA B149 1 or Propane Storage and Handling Code B149 2 or the Standard for Recreational Vehicles AN...

Page 6: ...ed and used as replacements Note Rocks are not to exceed a maximum weight of 2 kg 4 4 lb Never use a lid to extinguish the flame on your Outland Firebowl The lid and carry straps Cover Carry Kit is to...

Page 7: ...91 m 36 in from the gas cylinder WARNING Ensure that no parts of your body clothing or any other combustible material are above the burner before during and after ignition STEP 6 Your firebowl is equi...

Page 8: ...WHAT IS AN EXCESS FLOW SAFETY VALVE EFV The EFV is a safety mechanism contained within the gas regulator The purpose of the EFV is to restrict the gas supply if too much gas is flowing too quickly thr...

Page 9: ...INTENANCE Your Outland Firebowl requires periodic maintenance to keep it in good running order Follow the steps below to ensure your appliance will provide you with the best possible performance STEP...

Page 10: ...ce any objects other than supplied rocks inside the burner component of the OUTLAND Firebowl Do not add wood or any other materials to the fire It is designed to safely combust gas only Do not connect...

Page 11: ...usly a nest or blockage of the burner tube can cause a back flame event damage to your appliance or even extreme operator injuries Mounting Screws and Nuts STEP 4 Remove the gas valve body assembly ST...

Page 12: ...Living product for proof of purchase and warranty at https outlandliving com register products Registration in English only For more warranty information and details please contact FMI Brands Inc at i...