Page 1: ... Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit the Viking website at vikingrange com F20921B EN 070113 Viking Use Installation Guide Outdoor 15 Wide Double Side Burners ...

Page 2: ...ness and which are known to cause cancer birth defects or other reproductive harm For example benzene is a chemical which is part of the gas supplied to the cooking product It is consumed in the flame during combustion However exposure to a small amount of benzene is possible if a gas leak occurs Formaldehyde and soot are by products of incomplete combustion Properly adjusted burners with a bluish...

Page 3: ...er on the regulator assembly to the 3 8 male flare adaptor on the unit DO NOT forget to place the installer supplied gas valve in an accessible location Natural Fixed Piping Connection Connection Standard Residential 1 2 ID gas service line 1 2 NPT male with 1 2 flare adapter Operating Pressure 4 0 W C P Nat Supply Pressure 6 to 14 W C P Nat If in excess of 14 W C P a step down regulator is requir...

Page 4: ...w the LP Propane tank to withstand a horizontal tipping force equal to the weight of the tank without tipping over The tank can not tip over or deflect more than 1 00 inch when a 38 lb horizontal force is applied to a 20 lb LP Propane tank Connection 1 2 1 3 cm NPT male with a 3 8 95 flare adapter Operating Pressure 10 0 W C P To connect to LP Propane regulator hose assembly Although the flow of g...

Page 5: ...nt concerns such as exposure to wind proximity to traffic paths and keeping gas supply lines as short as possible Locate only in a well ventilated area Never locate in a building garage breezeway shed or other such enclosed areas 4 In a built in construction where an LP Propane tank is going to be used there MUST be some type of support braces cut out etc to prevent tank from moving within the ins...

Page 6: ...m the burner turn the air shutter clockwise to reduce the amount of air to the burner Once adjusted turn the burner off tighten the set screw on the air shutter replace the valve panel for the side burners and the grate support burner bowls and grates for the side burners To 11 Air Shutters Orifice 1 3 8 cm 3 8 95 cm FLAME HEIGHT 1 At least one ventilation opening shall be provided on the exposed ...

Page 7: ...r other damage which could require replacement prior to use Make sure all burner control knobs are off Do not attempt to light the burners if the smell of gas is present Check the connection with a soap and water solution after attaching the hose Make sure there is gas in the tank and the tank is upright CAUTION Wait at least five minutes before relighting a hot grill to allow any accumulated gas ...

Page 8: ...l permanently discolor stainless steel Wipe up any spills immediately Do not use abrasive cleaners steel wool pads or abrasive cloths on stainless steel parts Under rare conditions such as an extremely salty environment small amounts of rust may accumulate on stainless steel parts These small amounts of surface rust can easily be removed by applying Soft Scrub Gel to a damp sponge and wiping with ...

Page 9: ... owner of the product during the term of the warranty and applies to products purchased and located in the United States and Canada Products must be purchased in the country where service is requested If the product or one of its component parts contains a defect or malfunction during the full warranty period after a reasonable number of attempts by the warrantor to remedy the defect or malfunctio...