9
Set-Up
Natural Gas
Ensure that the service supplying the fire pit is fitted with a conveniently
positioned shut off valve with easy access. The shut off valve MUST
NOT be inside the appliance!
Requirements
Always check the rating plate to make sure the gas supply you are hook-
ing up to is the gas type the fire pit is manufactured for.
The installation of this appliance must conform with local codes or, in
the absence of local codes, to the national fuel gas code, ANSI Z223.1a-
1998. Installation in Canada must be in accordance with the standard
CAN/CGA-B149.2, Propane Installation Code. Natural gas connection
must be performed by a licensed contractor or local gas company rep-
resentative.
Ensure that the service supplying the fire pit is fitted with a conveniently
positioned shut off valve with easy access.
Installation
Connect the incoming gas supply line to the on/off gas valve of the ap-
pliance. Make certain ALL gas connections are tight, turn the on/off
valve at the unit to the ‘on’ position and use soap and water to test
for leaks. Gas will be released at the burner for this duration. DO NOT
USE AN OPEN FLAME AND REMOVE BATTERY FROM IGNITER BEFORE
PERFORMING THIS TEST. An authorized gas appliance installer must
provide this installation service. Note that the correct natural gas orifice
must also be installed prior to fuel line hook up to maintain proper flame
height and clean burn of fuel.
Connect to the gas source and perform a leak test.