D. Frame the Fireplace
Figure 6.4 shows typical framing using combustible materials (2x4 lumber shown).
• Observe all required air space clearances to combustible materials as shown in Figure 6.1 & 6.2.
• Framing across the top of fireplace must be above top standoffs.
Figure 6.4 Framing the Fireplace
C. Sidewalls/Surrounds
• Adjacent combustible sidewalls must be located a minimum of 12 in. (305 mm) from the fireplace opening.
• Combustible and non-combustible mantel legs, surrounds and stub walls may be constructed within the gridded area,
Figure 6.3.
Figure 6.3 Mantel Leg or Wall Projections (Acceptable on both sides of opening)
B
C
A
Header MUST NOT be notched!
Model
A
B*
C**
in.
42
21 1/2
39 3/4
mm
1067
546
1010
in.
48
21 1/2
39 3/4
mm
1219
546
1010
ODVILLA-36
ODVILLA-42
* If interior of chase will be drywalled, add the thickness to
this measurement.
** Adjust header height for a raised floor under fireplace.
14 1/2 in.
(368 mm)
framing
Model
A
Fireplace
opening
B
Outside
Dimensions
36 in.
41 in.
914 mm
1041 mm
42 in.
47 in.
1067 mm
1194 mm
ODVILLA-42
ODVILLA-36
B
A
9 3/4 in.
[248 mm]
12 in.
[305 mm]
12 in.
[305 mm]
11 1/4 in.
[286 mm]
FLUSH
FRONT
4 in.
[102 mm]
BRICK
FRONT
50° angle
39° angle
Outdoor Lifestyles by Hearth & Home Technologies • ODVILLA Wood Owners/Install • 4072-345 Rev A • 08/22