Outdoor Lifestyles • ODMEZG-36 Installation Manual • 4601-901 Rev. B • 10/17
Figure 3.6 Clearances to Combustibles
MINIMUM FRAMING DIMENSIONS*
A
B
C
D
E
F
G
H
I
J
Rough
Opening
(Vent Pipe)
Rough
Opening
(Height)
Rough
Opening
(Depth)
Rough
Opening
(Width)
Clearance
to Ceiling
Combustible
Floor
Combustible
Flooring
Sides of
Appliance
Front or
Rear of
Appliance
Clearance
to Ceiling
MEZG-36
in.
10
38-1/2
18-1/8
51-3/4
44-1/2
0
0
****
1
48
68
mm
254
1682
493
1314
1130
0
0
25
1219
1727
F
G
H
E
I
J
E=MEASUREMENT FROM TOP
OF FIREPLACE OPENING
TO CEILING
J=MEASUREMENT FROM
BOTTOM OF FIREPLACE
TO CEILING
C
A
B
D
HEADER
DEPTH**
HEADER
DEPTH**
APPLIANCE MAY BE
INSTALLED OFF OF FLOOR***
* = Adjust framing dimensions for interior and exterior sheathing (such as sheetrock and drywall)
**= Header depth not to exceed 3-1/2 inches.
***= If appliance is installed off of floor, maintain required clearances to combustibles.
Construct platform in accordance with local building codes.
****= Clearances to Combustibles - Follow these instructions carefully to ensure safe installation. Failure to
follow instructions exactly can create a fire hazard.
The appliance cannot be installed on a carpet, tile or other
combustible material other than wood flooring. If installed on carpet or vinyl flooring, the appliance shall be
installed on a metal, wood or noncombustible material panel extending full width and depth of the appliance.
W