When selecting a location for the appliance it is important
to consider the required clearances to walls. See Figure
3.6.
WARNING! Risk of Fire or Burns!
Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be lo-
cated out of traffic and away from furniture and draperies.
NOTICE:
Illustrations reflect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation could vary due
to individual design preference.
Figure 3.5 Appliance Locations
It is important to follow the framing and finishing instruc
-
tions step by step to ensure proper placement of fireplace
in the surrounding framing/finishing materials.
51-3/4”
Refer to Section 10 for hearth, mantel and
wall projection information.
18-1/8”
51-3/4”
18-1/8”
Mantel Clearances
NOTE: The combustible area above the facing must
not protrude more than
3
⁄
4
" from the facing. If it does,
it is considered a mantel and must meet the mantel
requirements listed in this manual.
6”
5”
3”
4
¹⁄₂
”
45°
1”
3
¹⁄₂
”
FP2423
mantel leg
1
¹⁄₂
”
2
¹⁄₂
”
FP2746
Side of Fire
-
place Opening
Figure 3.4 - Mantel clearances
Top View
9"
(229 mm)
12"
(305 mm)
6"
(152 mm)
12" (305 mm)
6" (152 mm)
2
¹⁄₂
"
(64 mm)
FP2745
mantel clearances
Wall
Stud
Insulation
Board
Standoff
Top of Fireplace
Opening
FP2745
Side View
►