Outdoor Lifestyles by Hearth & Home Technologies Inc. • Carolina • 4066-300 • Rev. Z • 11/13
4
1
1
Listing and Code Approvals
A. Appliance Certi
fi
cation
This product is listed to ANSI standards for “Outdoor Open-
Flame Decorative Gas Appliances” and “Gas Fired Appli-
ances for Use at High Altitudes”.
MODELS:
CARODG36I, CARODG36IL,
CARODG42I, CARODG42IL
LABORATORY:
Underwriters Laboratories, Inc. (UL)
TYPE:
Outdoor Open-Flame Decorative Gas Appliances
STANDARD:
ANSI Z21.97-2008
Note:
This installation must conform with local codes. In the
absence of local codes you must comply with the
National
Fuel Gas Code, ANSI Z223.1-latest edition
in the U.S.A.
and the
CAN/CGA B149 Installation Codes
in Canada.
Models
Min/Max Input
BTUH
Ori
fi
ce Size
(DMS)
CARODG36I (NG)
36,000/55,000
#27 / .144
CARODG36IL (LP)
29,000/50,000
#46 / .081
CARODG42I
33,000/65,000
#24 / .152
CARODG42IL
37,000/62,000
#43 / .089
B. BTU Speci
fi
cations
Note:
This appliance, when installed, must be electrically
grounded in accordance with local codes, or in the absence
of local codes with the
National Electrical Code, ANSI/
NFPA 70
, if applicable.
G. Fuel
This appliance must not be used to burn solid fuel.
C. High Altitude Installations
NOTICE:
If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility or
authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA: Reduce input rate 4% for each 1000 feet above
2000 feet.
• In CANADA: Reduce input rate 10% for elevations
between 2000 feet and 4500 feet. Above 4500 feet, consult
local gas utility.
Check with your local gas utility to determine proper ori
fi
ce
size.
D. Non-Combustible Materials Speci
fi
cation
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing
ASTM E 136, Stan-
dard Test Method for Behavior of Materials in a Vertical
Tube Furnace at 750 ºC
shall be considered noncombus-
tible materials.
F. Electrical Codes
If this appliance will be wired, the following applies:
NOTICE:
This appliance must be electrically wired and
grounded in accordance with local codes or, in the absence
of local codes, with
National Electric Code ANSI/NFPA 70-
latest edition
or the
Canadian Electric Code CSA C22.1.
E. Combustible Materials Speci
fi
cation
Materials made of or surfaced with wood, compressed
paper, plant
fi
bers, plastics, or other material that can ignite
and burn, whether
fl
ame proofed or not, or plastered or
unplastered shall be considered combustible materials.
Note:
See Section 6.A. for
fl
ame adjustment.