Step 1: 

Lower the 

Burner Module 

through 

the umbrella hole in your table or 
other mounting location. 

1. 

Step 2: 

Slide the 

Securing Bracket 

up the threaded rod positioned between the ignition wires 

and brass fitting at the top of the assembly 

facing in the direction shown below

. Secure 

with a wingnut. Your burner assembly is now secured to the mounting surface.  

2. 

Wingnut 

Summary of Contents for Intrigue INT-1

Page 1: ...tely call your gas supplier from a neighbor s phone Follow the gas supplier s Instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by...

Page 2: ...f durable use and trouble free enjoyment Homeowner Reference Information Model name ______________________________ Date of purchase installation_________ Serial Number ___________________________ Loca...

Page 3: ...pect the Appliance and Components 6 C Framing enclosures for LP Supply Systems 7 3 Fuel Information 8 A Fuel type 8 B Gas Pressure requirements 8 C Gas connection 8 D LP Gas supply information 9 4 Set...

Page 4: ...ed in accordance with IAS US requirements for Outdoor Gas Fireplaces Draft 4 96 and CSA requirement for Outdoor Gas Fireplaces CR 97 003 for Canada and has been listed by Underwriters Laboratory UL fo...

Page 5: ...ry for optional remote not included Required for remote operation system What s Included 2 Getting Started Propane hose and regulator for standard tank models Regulator for 1 lb tank models OR Wing nu...

Page 6: ...on and use of any damaged components Modification of the burner assembly Installation other than as instructed by the Outdoor GreatRoom Company Any such action may cause a fire hazard WARNING Do NOT u...

Page 7: ...a of 10 square inches 64 5 sq cm If ventilation openings at floor level are in a side wall there must be at least two openings The bottom of the openings must be at floor level and the upper edge can...

Page 8: ...t be disconnected from the gas supply piping system during any pressures in excess of psi 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual shut...

Page 9: ...of excessive abrasion or wear or if the hose is damaged the hose assembly must be replaced prior to the appliance being put into operation Use only the replacement hose assembly specified by the manuf...

Page 10: ...r table or other mounting location 1 Step 2 Slide the Securing Bracket up the threaded rod positioned between the ignition wires and brass fitting at the top of the assembly facing in the direction sh...

Page 11: ...tip to the port labeled I Tighten Step 3 Slide the Control Module up the threaded rod through the holes shown at lower left Thread a wingnut onto the threaded rod to hold it in place while performing...

Page 12: ...ile they re mounted under the table Step 7 Moving now to the top side of your table Remove the nuts from the threaded rods at right Set the Venturi Top on the Burner Module lining up the threaded rods...

Page 13: ...tep 12 Concealing the valve assembly and Placing the Control switch Your Intrigue includes a cloth bag for concealing and protecting your product s inner workings To use bag simply open one end slide...

Page 14: ...at least annually by a qualified service person More frequent cleaning may be required as necessary It is imperative that control valve burner and air passageways in venturi top be kept clean Before i...

Page 15: ...e 2 Open propane tank valve if equipped 3 Locate three position switch and set to ON position I 4 Burner should beep twice and begin sparking During first use it may take longer than usual for flame t...

Page 16: ...uide should only be used by a qualified service technician Symptom Possible Causes Corrective Actions Igniter sparks but will not light Tank may be empty Replace tank with a full one Spark may not be...

Page 17: ...connections and fittings Risk of Fire Delayed ignition or explosion Exposure to combustion fumes Odors WARNING Risk of injury or property damage Before servicing Turn off utilities to appliance Ensur...

Page 18: ...oom dealer please call 866 303 4028 NOTES 8 Reference Materials Part description Part Number QTY 10 Glass cylinder INTRIGUE GLASS 1 Venturi disc INTRIGUE VFTOP 1 Battery Pack INTRIGUE BATT 1 Electroni...

Page 19: ...repaired or replaced before The Outdoor Greatroom Company has been afforded a reasonable opportunity to inspect the Product This warranty is limited to the replacement or repair of defective componen...

Reviews: