WHAT’S INCLUDED:
HGI-31 NATURAL GAS
• Multi-speed fan
• Set-up for Natural Gas
• Multi-level ember bed setting
• Glowing embers
• Flexible metal gas line with shut-off
• Owner’s Manual
• Remote Control
1
Listing and Code Approvals
A. APPLIANCE CERTIFICATION
B. SPECIFICATIONS
MODEL
ORIFICE SIZE
LP - #54
NG - #41
HGI-31
MAX INPUT
BTU
MODEL:
HGI-31 Vented Gas Insert
LABORATORY:
Underwriters Lab (UL)
TYPE:
Sealed combustion gas insert for
use in wood burning fireplaces.
STANDARD:
ANSI Z21.50-2014 Vented
Gas Fireplace / CSA 2.22-2014
HGI-31 has been tested in accordance
with US and Canadian requirements for
vented gas fireplaces, reference
Natonal
Fuel Gas Code
ANSI Z223.1/NFPA54 or
the
Natural Gas and Propane Instalation
Code
CSA B149.1, and operating as
described in these installation and
operating instructions.
The installation must conform with local
codes or, in the absence of local codes, to
ANSI Z21-50 or CSA 2.22-2014.
The appliance, when installed, must be
electrically grounded in accordance with
local codes or, in the absence of local
codes, with the
National Electrical Code
,
ANSI/NFPA 70, or the
Canadian Electrical
Code, Part 1
, CSA C22.1.
22,000 BTU/hr - high
16,500 BTU/hr - low
24,400 BTU/hr - high
19,100 BTU/hr - low