CAUTION
If burner does not light OR if burner flame is accidentally extinguished, turn the regulator control knob to OFF, wait 5 minutes, and try
again. If the burner does not ignite with valve open OR if burner flame is accidentally extinguished after lighting, gas will continue to flow
out of the burner and could accidentally ignite with risk of injury.
Turning the appliance on
1.
Turn LP tank ON by turning OPD handle wheel counterclockwise to a full stop, turn the regulator
control valve to ON position, turn the burner clockwise, self-ignition should occur at first ¼ turn,
you should hear the igniter activate. Check for flame at burner.
Burner Flame Check
2.
Light burner, rotate the regulator control knob from HIGH to LOW. You should see a smaller flame
in LOW position than seen on HIGH. Always check flame prior to each use. A blue flame with little
or no yellow flame provides the best heat.
Turning the appliance off
3.
Turn the burner counterclockwise to OFF position, turn the regulator control valve to OFF position,
turn LP tank OFF by turning OPD hand wheel clockwise to a full stop.
CAUTION
Regularly check and clean the burner venturi tube for insect nests. A clogged burner can lead to fire beneath the appliances. Spiders’
nests or wasps’ mud inside the burner may cause fire. If a fire occurs, immediately turn off gas supply at LP tank valve. Refer to the Care &
Maintenance section for details on cleaning and maintaining the burners.
WARNING
Leak Testing Valves, Hoses and Regulator
1.
Turn LP tank valve and regulator control knob to OFF.
2.
Be sure regulator is tightly connected to LP tanks.
3.
Completely open LP tank valve by turning OPD hand wheel counterclockwise. If you hear a
rushing sound, turn gas off immediately. There is a major leak at the connection. Correct before
proceeding.
4.
Brush soapy solution onto indicated connections shown below in A.
5.
If ‘growing” bubbles appear, there is a leak. Close LP tank valve immediately and retighten
connections. If leaks cannot be stopped, do not try to repair. Call for replacement parts. Order
new parts by giving the serial number, model number and name of items needed to the
Customer Service Center at 1-888-922-2336. Use only replacement parts specified by
manufacturer.
6.
Always close LP tank valve after performing tank leak test by turning OPD hand wheel clockwise.
CAUTION
All cleaning and maintenance should only be done when the appliance is cool and with the fuel supply turned off at the LP tank. DO
NOT clean any part in a self-cleaning oven. The extreme heat will damage the finish. Refer to the Care & Maintenance section for details
on cleaning and maintaining the appliance.