background image

031-331-B1-001, Rev. A (11/2015)

031-331-B1-001, Rev. A (11/2015)

4

5

PV Module Connections

Pole-mounted systems will use either Alpha Technologies' PWE-3 or PWE-6 enclosures. Refer to the 

Alpha Pole Mount Installation 

Guide 

(745-968-C0) for complete installation and configuration instructions. Read and follow all safety instructions contained in 

the manual.

IMPORTANT:

The enclosure must only be installed by qualified personnel.

Enclosure Installation

Mounting the Photovoltaic (PV) Module

PV modules are secured to the mounting rails using 1/4" x 3/4" bolts, with hardware tightened to a torque setting of 7 ft-lb.

Refer to 

ET Solar Series Photovoltaic Modules User Manual

 

for additional information.

Warning: Electrical Hazard

Photovoltaic modules convert light energy to DC power and are designed for outdoor use. Proper design of support structures 
is the responsibility of the system designer and installer. Cover modules with opaque material until modules are installed and 
connected to the PV circuit breaker.

WARNING: Personal Injury

Due to the weight and size of the PV module, two installers are required to attach the PV module to the rails. 

1

2

1

2

PV module/SmartHarvest Charge Controller connections

PV module positive (+): Connect to the lower position of PV input circuit breaker.

PV module negative (–): Connect to the charge controller PV negative (–). 

PV module/TriStar Charge Controller connections

PV module positive (+): Connect to the lower position of PV input circuit breaker.

PV module negative (–): 

Connects directly t

o the negative bus bar. 

CAUTION: Hazard to Equipment

In systems configured with a SmartHarvest Charge Controller:

 Connect PV module negative (–) directly to PV negative (–) 

point on the charge controller.

In systems configured with a TriStar Charge Controller: 

Connect PV module negative (–) to the negative bus bar; the connection 

between the negative bus bar and PV negative (–) on the charge controller is pre-wired.

Each system requires the PV module connections to be made as shown above. Connecting the PV modules with reversed polarity 
will damage the charge controller.

IMPORTANT:

All PV modules must be wired in series.

1/4" x 3/4" Bolt 
Flat Washer

Flat Washer

Lock Washer

1/4" Nut

PV Module wiring to SmartHarvest Charge Controller

1

2

Positive (+) 

Negative (−) 

PV Module

Input

PV Module wiring to TriStar Charge Controller

1

2

PV Module

Input

Positive (+) 

Negative (−) 

Illustration courtesy of DPW Solar / Preformed Line Products

Summary of Contents for smartharvest

Page 1: ...ll Battery Owner s Manual OutBack Power Technologies p n 900 0127 01 00 Audience This guide is intended for experienced installers familiar with the mechanical and electrical requirements of photovolt...

Page 2: ...procedure components could create hazards obstructing free movement and leading to serious bodily injury These hazards are at head eye level The use of head and eye protection is required IMPORTANT T...

Page 3: ...attach the PV module to the rails 1 2 1 2 PV module SmartHarvest Charge Controller connections PV module positive Connect to the lower position of PV input circuit breaker PV module negative Connect...

Page 4: ...acid contacts skin or clothing wash immediately with soap and water If acid enters the eye immediately flood it with running cold water for at least 20 minutes and get medical attention as soon as po...

Page 5: ...Charge Controller connection detail including optional battery sense wiring and remote temperature sensor wiring Battery temperature sensor optional connect to battery terminal Battery sense wire conn...

Page 6: ...ads 2 Recharge battery Yellow LED not on Charge battery Charging to wrong voltage 1 Check position of battery selection jumper 2 Check installation of thermistor Load not powered Check minimum load fo...

Page 7: ...tive String 3 positive String 1 negative String 2 negative String 3 negative Load connections Battery bus to LVD positive LVD negative to negative bus bar LVD Load to Load output circuit breaker DC ou...

Page 8: ...Confirm the polarities of the PV module wiring and Battery string wiring are correct 2 Close the connected battery string breakers 1 through 3 3 Close the master battery disconnect The LEDs on the cha...

Page 9: ...0 Vdc indicating the system is offline A B C D IllustrationofMorningstarTriStarMPPT 30ChargeControllercourtesyofMorningstarCorp A PV module breaker B DC bus breaker C Low voltage disconnect LVD D Load...