background image

User manual for OTTO HEUSS universal stop motor PCB RM-2

 

 

Otto Heuss GmbH 

 

 Page 

8

 of 

8

 

8

 

ESD-warning 

Please do not touch the electronic modules without sufficient ESD protection.  Like 

almost all electronic components, the modules are sensitive to ESD. For this reason they 

are delivered in an antistatic packaging. To protect the module from damage, the usual 

ESD regulations must be observed. 

Electrostatic discharge (ESD) is a spark or breakdown caused by a large potential difference, which 

causes a short, high electrical voltage pulse on an electrical device. Under unfavourable conditions, 

this voltage pulse can damage electrical components in the device. The cause of the potential 

difference is usually a charge due to frictional electricity (triboelectric effect) or influence. Frictional 

electricity also occurs, for example, when walking over a carpet, whereby a person can be charged to 

approx. 30.000 V (from Wikipedia, the free encyclopaedia). 

9

 

Precautionary measures 

To ensure safe operation, the following precautions must be observed: 

 

Avoid placing the unit near heat sources and/or in humid and/or dusty places. 

 

To avoid damage, the unit must be securely and stably fastened due to high workloads. 

 

An organ is an electrical installation and must be wired, connected and commissioned 

professionally and in accordance with applicable standards and regulations. 

 

Avoid strong vibrations during transport, as these can damage the electronics. 

 

The device should not be placed near installations that emit high-frequency waves, such as 

television sets, radio receivers, microphone systems, transmitter masts, etc. 

 

Strict care must be taken to ensure that no liquids or metal shavings 

reach the device, as these can cause damage. 

 

Do not carry out any unauthorized work on the electronic system. 

 

In the event of a defect, contact the manufacturer. 

 

Never reach between magnet and attachment. There is a high workload. 

Danger of crushing! 

10

 

Warranty 

 

The company Otto Heuss GmbH provides a two-year warranty from the date of delivery. 

 

Otto Heuss GmbH is not responsible for damage caused by incorrect handling. 

 

The company Otto Heuss GmbH assumes no responsibility for cancelled or impaired concerts, 

events or performances. 

11

 

Disposal 

Electrical appliances that are no longer required or are defective should not be 

disposed of in the household waste; they must be taken to a local collection point for 

proper disposal. 

Used batteries and electrical appliances must be disposed of separately in 

accordance with applicable regulations.

 

Summary of Contents for PCB RM-2

Page 1: ...rdware Version Rev 7 Date of issue 04 03 2020 Page 1 User manual for OTTO HEUSS universal stop motor PCB RM 2 For the operation of Stop action sliders el dual stop action sliders el mech couplers and...

Page 2: ...ts couplers and much more in 14V and in 24V in both DC and AC voltage To simplify the variants and to create new or improve existing functions the circuits will in future only be divided into two vari...

Page 3: ...pective manual of the switch cabinet 4 Electrical connection 4 1 Mounted PCB All connection terminals are designed with push in connection technology This allows rigid conductors or flexible conductor...

Page 4: ...al pulse is required AB OFF Connection for the signal to switch off the motor this is only used for the electrical mechanical dual stop action version otherwise no cable connection required Input can...

Page 5: ...must be connected to the two Schalter Switch connection points on the side of the board Switch 5 If this switch is set to ON the inputs Setzer AN Setter ON and Setzer AB Setter OFF operate by a negat...

Page 6: ...gan is switched on the motors automatically energize one side to match the ACTUAL state of the sliders to the SET state of the switches 6 2 Dual electrical mechanical stop action motor Combination of...

Page 7: ...orce when the coupler is activated The buttons AN ON and AB OFF can be used to test the coupler setup After pressing ON the coupler remains switched on until AB is pressed 6 4 Tremulant motor Tremulie...

Page 8: ...and stably fastened due to high workloads An organ is an electrical installation and must be wired connected and commissioned professionally and in accordance with applicable standards and regulations...

Reviews: