―E14―
6. CONNECTION PROCEDURE (continued)
6.4 Connecting of the Gas Hose
WARNING
●
You may suffer from danger of suffocation caused by lack of oxygen when
shield gas keeps flowing in a closed place. Be sure to turn off the shield gas at
the main when the welding power source is not in use.
WARNING
●
Be sure to connect the gas hose after fixing to the stand, as physical injuries may cause
from falling down of gas cylinder.
●
Attach a proper gas regulator to the gas cylinder. Failure to observe the demand may cause
in physical injuries. The gas regulator for high pressure gas must be used.
How to Make Gas Connection
1. Firmly connect the gas hose to the gas supply inlet located on the rear side of the wire feeder.
2. Mount the gas regulator on the gas cylinder by tightening the nut for attaching the gas cylinder .
3. Connect the gas hose to the gas supply outlet on the gas regulator.
NOTE: Firmly tighten the nuts using a monkey wrench, etc. to connect the gas hose and gas
regulator.
Gas cylinder
Gas regulator
Gas inlet