For more detail information of e x
ternal sync, operation.
Please
contact to OTARI dealer.
13
Microphone
ATTENUATOR Switch
Used to adjust the sensitivity of
the microphone amplifier in ac
cordance with the microphone's
input level.
ATT
Minimum Input
(Sensitivity)
0 dB
-70 dBm
-20dB
-50 dBm
OFF
Shorted to the
ground
14
REF FLUX
Selector Switch
This switch is used for setting
the recording level:
"High",
"Medium", and "Low".
Located on the Amplifier front
panel are 3 LED Ref Flux Selector
Indicator displays which indicate
the position of the switch.
(185/250/320)
Position
Flux
Relative
Level
Test Tape
Recording Tape
to be used
Low
185 nWb/m*
0 dB
Ampex Operat
ing Level
Scotch 177
Ampex
641
Me
d
i
urn
250 nWb/m*
+
2.6 dB
MRL NAB
Re ference
Flux
Scotch 206, 207,
226, 250
Ampex
406, 407,
456
High
320 nWb/m**
+3.8 dB
BASF or MRL
IEC Standard
IEC Equaliza
tion
* Short circuit flux
** Open circuit flux
15
EQUALIZER Selector
Switch
The two-position EQUALIZER selec
tor switch is used to select
either LEC or NAB equalization.