SECTION IV.
GENERAL INFORMATION OF MAINTENANCE
4.1
TEST AND MAINTENANCE EQUIPMENT REQUIREMENTS
All maintenance, electronic, and mechanical test equipments re
quired during maintenance, alignment, and adjustment of the
recorder are listed in Table 4-1 and the standard test tapes are
listed in Table 4-2.
In addition, recommended maintenance periods are shown by accumu
lative hours of usage and/or elapsed period of time, whichever
comes first.
Equivalent equipment can be substituted for the equipment sug
gested in the t a b l e .
Table 4-1
Test and Maintenance Equipment
Equipment Type
Suggested Model
Used For
Period
Head cleaner
OTARI ZA-51B
Cleaning the
heads and guides
8 hours
Isopropyl or
denatured
alcohol
Any (OTARI Clean
ing Kit ZA-51B
contains the
above cleaning
m a t erials.)
Cleaning the tape
guides, capstan,
and pinch-roller
8 hours
Q tips
Any
Cleaning the
heads and guides
8 hours
Head
demagnetizer
Any
Demagnetizing the
heads and tape
guides
8 hours
Lubricating
oil
OTARI Lubricat
ing Oil PZ9E003
Lubricating the
capstan of the DC
servo control
motor
1,000 hours
or 6 months
Spring scales
500 g, 1 kg,
3 kg (0.16 o z ,
0.32 o z , and
0.10 lbs)
Any
(pushing and
pulling)
Mechanical
adjustment
1,000 hours
or 6 months
Vacuum cleaner
and brushes
Any
General cleaning
1 month
4-1