OT Systems FT100 Series Installation And Operation Manual Download Page 8

FT100 Series Installation & Operation Manual 

 

www.ot-systems.com

 

 

 

 

 

3.3  Card module installation 

a) 

Insert the card module into the FT-C18 chassis along the top and bottom card guides of an 

empty slot and push the card into the multi-pin socket at the rear firmly.   

b) 

Repeat the above procedure for all the rest card modules. Unused slots must be covered 

with blank panels (provided separately). 

c) 

Once  the  chassis  is  powered  up,  check  that  the  red  POWER  LED  on  the  front  and  back 

panels of the card modules are lit. If not, check the power supply cable connections between the 

chassis and the power supply socket. For failures of individual card’s POWER LEDs, check the 

corresponding card modules, whether they have been inserted properly. 

d) 

Connect  all  the  signal  inputs  and  outputs  at  the  back  of  the  unit  with  appropriate  cables: 

fiber optic cable for optical link and BNC cable for video input/output (Tx/Rx). 

e) 

With all the signals available at the input and output ports, check the status of LEDs located 

on the unit

.

 With correct status of each LED, installation is now completed [for LEDs status, see 

Operational Guides

 on this manual’s section 

(5)

]. 

 

(4)  Cable Connections & Setup Procedures 

4.1  System cable connections 

Signal Type 

Cable Type   

Connector 

Optical 

Single-mode or Multi-mode fiber 

ST (or FC) Connector 

Video 

Coaxial Video Cable 

BNC Connector 

 

Typical System Cable Connections Diagrams: 

 

 

Standalone Transmitter     

 

 

 

 

Standalone Receiver 

 

Fig 4.1 

Standalone unit to Standalone unit connection diagram 

 

Summary of Contents for FT100 Series

Page 1: ...All Digital Fiber Optic Manufacturing Specialists Installation and Operation Manual FT100 Series 10 bit Digital Series 1 ch Video Fiber Optic Converter OT Systems Ltd 2009 Rev 1 1...

Page 2: ...ode Receivers FT100 SSRSA FT100 SSRLSA Multi Mode Transmitter FT100 SMTSA Multi Mode Receiver FT100 SMRSA Card Modules Single Mode Transmitters FT100 SST FT100 SSTL Single Mode Receivers FT100 SSR FT1...

Page 3: ...able 5 3 INSTALLATION 6 3 1 General 6 3 2 Standalone unit installation 6 3 3 Card module installation 7 4 CABLE CONNECTIONS SETUP PROCEDURES 7 4 1 System cable connections 7 4 2 Ground connection 9 5...

Page 4: ...I invisible optical radiation is possible when the internal fiber optic connector is disconnected while the unit is powered up Caution Any access to the controls adjustments or performing operations w...

Page 5: ...ssion of forward video For the single mode transmission we also offer specifically designed products for long haul transmissions up to 60km Their model names include a letter L in the suffix e g FT100...

Page 6: ...Mode FT100 SMTSA Multi mode 1 Ch Video Transmitter Standalone Unit FT100 SMRSA Multi mode 1 Ch Video Receiver Standalone Unit Card Modules Single Mode FT100 SST Single mode 1 Ch Video Transmitter Card...

Page 7: ...e inside and a total of 18 cards can be housed inside the chassis 3 2 Standalone unit installation a Mount the standalone unit onto a fixture e g a plank either on the wall or on a flat surface with f...

Page 8: ...ER LEDs check the corresponding card modules whether they have been inserted properly d Connect all the signal inputs and outputs at the back of the unit with appropriate cables fiber optic cable for...

Page 9: ...ion Manual www ot systems com 8 Standalone Transmitter Card Module Receiver Fig 4 2 Standalone unit to Card Module connection diagram Card Module Transmitter Card Module Receiver Fig 4 3 Card Module t...

Page 10: ...lightning and other power surges in addition to the incorporation of the surge protective devices into the products a screw is provided on the Standalone cabinets Fig 4 4 It is highly recommended that...

Page 11: ...the OL LED on the Tx is not lit because optical signal from the Rx to the Tx is always inactive Signal Ports OPT ST or FC Optical Connector for fiber cable connection VIDEO IN BNC Video Connector for...

Page 12: ...Impedance 75 Ohm Input Output Level 1 0 Vp p typical Differential Gain 1 typical Differential Phase 1 o typical SNR 65dB POWER Power consumption 12VDC 3W Power Supply Standalone Unit FT PA12V DC Adap...

Page 13: ...fer to the OT Systems Products Warranty Statement for details Access to the statement is available in our company website at www ot systems com 9 Contact Information OT Systems Ltd Hong Kong Unit 1023...

Reviews: