OSTBERG IRB 1000x500 F3 EC Manual Download Page 10

12

F A U L T   D E T E C T I O N

W A R R A N T Y

M A I N T E N A N C E

O P E R A T I O N

For technical data please see the product label.
Before starting, make sure that:
•  the current does not exceed more than +5% of what 

is stated on the label.

•  the connecting voltage is in b6% to –10% 

of the rated voltage.

•  no noise appears when starting the fan.

The warranty is only valid under condition that the fan
is used according to this “Directions for  use” and a regu-
lar maintenance has been made and record. The war-
rantor is responsible only for the operation if approved

accessories are used. The warranty does not cover pro-
duct failures caused by accessories/equipment from
other manufacturers.

•  Before service, maintenance or repair begins, the fan 

must be tension free and the impeller must have 
stopped.

•  Attention, look out for sharp edges and corners.
•  Consider the weight of the fan when removing or 

opening larger fans to avoid jamming and contu-
sions.

Attention! 

Temperatures up to 85°C can be pre-

sent on the controller housing (only for EC motor).

• 

Waiting period of at least 3 minutes! 

(only for 

EC motor) Because of internal capacitors, danger of 
death exists even after switching off the device 
through directly touching the energized parts or due 
to parts that have become energized due to faults. 
The controller housing may only be removed or  
opened when the power line has been switched off 
and a period of three minutes has elapsed since swit-
ching it off.

•  When cleaning and maintaining, the fan always have 

to be secured when open, so it can’t fall down and 
cause injury.

•  The fan must be cleaned when needed, at least once 

a year to maintain the capacity and to avoid unba-
lance which may cause unnecessary damages on the 
bearings.

•  When cleaning the fan, high-pressure cleaning or 

strong dissolvent must not be used. Cleaning should 
be done without dislodging or damaging the impel-
ler.

•  The fan bearings are maintenance-free and should 

be renewed only when necessary.

•  Notice the weight of the fan when closing after 

inspection/cleaning.

•  Mount back all details in reverse order. Check that 

the fan is closed and locked before starting.

•  Make sure that there is no noise from the fan.

1. Make sure that there is power to the fan.
2. Cut the power and verify that the impeller is not 

blocked.

3. Check the EC motor with LED flashing code. For 

more information see page 13-14.

4. Check the thermal contact (for AC). If it is discon-

nected the cause of overheating must be taken care 
of, not to be repeated. To restore the manual ther-
mal contact, cut the power for a couple of 
minutes. Larger motors than 1,6 A may have manu-
al resetting on the motor. If it has automatic thermal 

contact the resetting will be done automatically 
when the motor has cooled.

5. Make sure that the capacitor is connected according 

to the wiring diagram (for AC).

6. If the fan still does not work, the first thing to do is 

to change the capacitor (for AC).

7. If nothing of this works, contact your fan supplier.
8. If the fan is returned to the supplier, it must be 

cleaned, the motor cable undamaged and a detailed 
nonconformity report enclosed.

E N G L I S H

Summary of Contents for IRB 1000x500 F3 EC

Page 1: ...SVENSK ENGLISH VERSION Bruksanvisning Directions for use IRB...

Page 2: ...svarig f r deras s kerhet Barn skall h llas under uppsikt f r att f rs kra att de inte leker med produkten Fl kten ska anv ndas f r transport av ren luft m a o den r ej avsedd f r transport av brand o...

Page 3: ...s efter 45 000 driftstim mar ca 5 rs kontinuerlig anv ndning f r bibeh l len fl ktfunktion Defekt kondensator kan orsaka skada EC MOTOR Varvtalsreglering av EC motor kan g ras med den inbyggda potenti...

Page 4: ...rts och dokumenterats Garantigivaren ansvarar enbart f r funktionen om godk nda tillbeh r anv nds Garantin omfattar inte fel p produkten som orsakats av tillbeh r utrustning av annat fabrikat S V E N...

Page 5: ...r ver Vid sjunkande temperatur Kontrollera 11 14 vakning f r att skydda den fr n skador stiger moduleringen propor kylning av sluten orsakade av alltf r h ga inre tempera tionellt igen regulatorn ture...

Page 6: ...ss lyckats D r det n dv ndigt att enkelt kunna terst lla eller st nga av str mmen 6 x Rel ej draget IGBT Fel EC enheten st ngs av anslutning Kortslutning mot jord eller kortslut nya f rs k till omstar...

Page 7: ...ektivet f r elektromagnetisk kompatibilitet EMC 2004 108 EG Harmoniserande standarder SS EN 61000 6 1 2007 Elektromagnetisk kompatibilitet EMC Generella fordringar Immunitet hos utrustning i bost der...

Page 8: ...sponsible for their safety Children should be supervised to ensure that they do not play with the appliance The fan is used for transportation of clean air mea ning not intended for fire dangerous sub...

Page 9: ...tion hours about 5 years of operation to secure maximum function Defective capacitor can cause damage EC MOTOR Speed regulating of EC motor can be done with the built in potentio meter 0 10 V An exte...

Page 10: ...off When cleaning and maintaining the fan always have to be secured when open so it can t fall down and cause injury The fan must be cleaned when needed at least once a year to maintain the capacity a...

Page 11: ...ls D1 24 V 10 V D1 24 V 10V bridged Digital In 1 not bridged 2 x Energized Active temperature monitoring terminals The device has an active temperature At sinking temperature the Check cooling 11 14 m...

Page 12: ...essary to have rotatable an enabling reset or to disconnect the power supply 6 x De energized IGBT Fault EC Controller switches off renewed terminals Shortcut earth or shortcut of motor attempt to sta...

Page 13: ...omagnetic Compatibility EMC 2004 108 EG Harmonised standards SS EN 61000 6 1 2007 Electromagnetic compatibility EMC Generic standards Immunity for residential commercial and light industrial environme...

Page 14: ...1270372 utg 1 AB C A STBERG Box 54 SE 774 22 Avesta Sweden Industrigatan 2 Avesta Tel 46 226 860 00 Fax 46 226 860 05 Email info ostberg com www ostberg com...

Reviews: