RJ-45 Port Indicators

Legend

Indicator

Description

100

OFF

No link

Green - ON

Port linked at 100Mbps

Green - Blinking at 10Hz Port data activity at 100Mbps

1000

OFF

No link

Green - ON

Port linked at 1000Mbps

Green - Blinking at 10Hz Port data activity at 1000Mbps

10 

(100+1000)

OFF

No link

Green - ON

Port linked at 10Mbps

Green - Blinking at 10Hz Port data activity at 10Mbps
Amber - Blinking at 1Hz

Port linked at 10Mbps and receiving AN Remote Fault

FDX

Green - ON

Port is configured for full-duplex via DIP-switch or has 

negotiated to full-duplex in AN mode

OFF

Port is configured for half-duplex via DIP-switches or Port 2 has 

negotiated to half-duplex in AN mode or Port 2 in AN mode has 

not established the correct connection

PSE

Green - ON

Port PSE is active

Amber - ON

Port PSE inactive

Amber - Blinking at 1Hz

Port PSE inactive due to resistance too low (< 15k ohms) or 

short circuit detected

Amber - Blinking at 10Hz Port PSE inactive due to resistance to high (33k to 500k ohms)
OFF

Port PSE disabled

RJ-45 LED Indicators

Specifications

AC/DC Adapter Temperature Derating

Total Available Wattage to RJ-45 Ports

Model

RJ-45 Ports

Watts 

Required

40

°C

50

°C

60

°C

70

°C

75

°C

GPoE/S

1

15 watts

Full Power

Full Power

Full Power

Full Power

Full Power

2

30 watts

Full Power

Full Power

Full Power

Full Power

Full Power

GPoE+/S

1

30 watts

Full Power

Full Power

Full Power

Full Power

Full Power

2

60 watts

Full Power

Full Power

Full Power

Full Power

50 watts 

The AC/DC Adapter Temperature derating table is not applicable to models with DC Terminal.  

The DC Terminal models will provide full PoE power over the operating temperature range of 

the module as long as the DC input power meets the requirements stated in the specification 

table.

Page 15

Page 16

Description

OmniConverter GPoE/S

10/100/1000BASE-T to 1000BASE-X or 100BASE-X Fiber Media 

Converter with PoE

Standard Compliances

IEEE 802.3, 
IEEE 802.3af (15.40 watts max)

PoE Supported Modes

IEEE Alternate A (Alt A), IEEE Alternate B (Alt B), Cisco Legacy and High 

Cap

Environmental

RoHS, WEEE and REACH

Frame Size

Up to 10,240 bytes

Port Types

Copper:

     

10/100/1000BASE-T (RJ-45)

Fiber:        100BASE-X (SFP)
                 1000BASE-X (ST, SC, LC, SFP)
                 1000BASE-BX (SC, SFP)

Cable Types

Copper: 

    

EIA/TIA 568A/B, Cat 5 UTP and higher

Fiber:        Multimode: 50/125, 62.5/125µm
                 Single-mode: 9/125µm

AC Power Requirements

(Models with AC/DC Adapters)

1 RJ-45 Port
100 - 240VAC/47 to 63Hz

0.21A @ 120VAC (typical)

2 RJ-45 Ports
100 - 240VAC/50 - 60Hz

0.36A @ 120VAC (typical)

DC Power Requirements
(Models with DC Terminals)

1 RJ-45 Port
+/-46 to +/-57VDC;  
0.46A @ 48VDC
3 Pin Terminal (isolated)

2 RJ-45 Ports
+/-46 to +/-57VDC;  
0.79A @ 48VDC
3 Pin Terminal (isolated)

Dimensions  (W x D x H)

4.5” x 6.0” x 1.0”  (114.3 mm x 152.4 mm x 25.4 mm)

Weight

Module Only:            1.1 lbs.  (498.9 grams)
Module w/ Adapter:

   

1.6 lbs.  (725.7 grams)

Operating Temperature
(See Temperature Derating Table)

Commercial:   0 to 50°C
Wide:           -40 to 60°C   (-20°C AC cold start)
Extended:    -40 to 75°C   (-20°C AC cold start)
Storage:       -40 to 80°C

Humidity 

5 to 95% (non-condensing)

Altitude 

-100m to 4,000m

MTBF (hours)

Module Only:        474,000

AC/DC Adapter:   100,000

Warranty

Lifetime warranty with 24/7/365 free Technical Support

Summary of Contents for OmniConverter GPoE+/S

Page 1: ...omnitron systems com support within ninety 90 days from the date of shipment During the warranty period Omnitron will at its option repair or replace a product which is proven to be defective with th...

Page 2: ...mage to equipment and personal injury WARNING Risk of electrical shock Customer Support Information If you encounter problems while installing this product contact Omnitron Technical Support Phone 949...

Page 3: ...port to accept 100BASE FX SFPs When an RJ 45 transceiver is installed in a SFP receptacle or for fixed fiber models setting this DIP switch to Up 100 position enables the port to operate at 100Mbps T...

Page 4: ...cing Modes for Models with 2 RJ 45 Ports Page 7 Select the appropriate powering source option based on the PD type Use the following table to determine the compatibility of the PD PD Type PSE Type Alt...

Page 5: ...0msec SW16 enables the module to return to the primary fiber port Port 1 after the fiber link has been restored for 6 seconds When SW16 is in the Down Off position return to primary is disabled inacti...

Page 6: ...aker Connect the power wires to the circuit breaker and switch the circuit breaker ON If any module are installed the Power LED will indicate the presence of power During the installation ensure that...

Page 7: ...ASE T Ethernet device Page 13 5 Verify Operation Verify the module is operational by viewing the LED indicators Power LED Indicators Legend Indicator Description Pwr OFF Unit not powered Green ON Unit...

Page 8: ...apter Temperature derating table is not applicable to models with DC Terminal The DC Terminal models will provide full PoE power over the operating temperature range of the module as long as the DC in...

Page 9: ...able or better Dimensions W x D x H 4 5 x 6 0 x 1 0 114 3 mm x 152 4 mm x 25 4 mm Weight Module Only 1 1 lbs 498 9 grams Module w Adapter 2 3 lbs 1043 3 grams Operating Temperature See Temperature Der...

Page 10: ...Appendix A Link Modes Page 19 Page 20...

Reviews: